MFE SCF: EMCP020E EXTRANEOUS DATA IN COMMAND returned when Thin Monitoring parameter ACTION=MESSAGE (MELDING) kodet.
Resumen: Feil verifisering av MELDING-parameteren med PARM_VERIFY = JA
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
When the PARM_VERIFY=YES parameter is specified in the ResourcePak Base initialization file, the incorrect EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ")" message is displayed.Eksempel:
SCF0301I SCF.THN.03.LIST = ACTION=MESSAGE(MESSAGE) SCF0313I SCF.THN.03.LIST=ACTION=MESSAGE(MESSAGE) EMCP010E * EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ) SCF0301I SCF.THN.03.LIST = FREQUENCY=REPEAT SCF0301I SCF.THN.04.LIST = PERCENT=(99,100) SCF0301I SCF.THN.04.LIST = DURATION=60 SCF0301I SCF.THN.04.LIST = ACTION=MESSAGE(MESSAGE) SCF0313I SCF.THN.04.LIST=ACTION=MESSAGE(MESSAGE) EMCP010E * EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ) SCF0301I SCF.THN.04.LIST = FREQUENCY=REPEAT
Causa
Dette skyldes et programvareproblem.
Resolución
Permanent korrigering:
- For Mainframe Enablers 8.5 er PTF-SF85111 utviklet for å løse problemet. Det er tilgjengelig for nedlasting fra Dells kundestøtte på Internett.
- For mainframe Enablers 8.4 er PTF SF84158 utviklet for å løse problemet. Det er tilgjengelig for nedlasting fra Dells kundestøtte på Internett.
Información adicional
EMCP020EOVERFLØDIGE DATA I KOMMANDO; FOUND: value
Cause
While parsing the input data stream, a syntax error was detected, and extraneous data was found (
Fant en syntaksfeil under analyse av inndataflyten).Handling
Korriger inndatadatastrømmen.
Merk for PTF-dekselet:
++PTF(SF85111) REWORK(2022038) . ++VER(Z038) FMID(SSCF850) PRE( SF85002 SF85042 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * USERS AFFECTED: Users of the THN Monitor * PROBLEM DESCRIPTION: Incorrect verification of the MESSAGE * parameter with PARM_VERIFY=YES * DESCRIPTION DETAIL: * * When the PARM_VERIFY=YES parameter is specified in the SCF * initialization file, the incorrect * EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ) * message is displayed. * * PROBLEM RESOLUTION: * * The code has been updated to correctly verify syntax of the * MESSAGE parameter. * * MODULES: ESFINI * SCFLIND * * ------------------------------------------------------------ * SF85111 7 Feb 2022 15:15:32 * ------------------------------------------------------------
Productos afectados
Mainframe EnablersPropiedades del artículo
Número del artículo: 000196982
Tipo de artículo: Solution
Última modificación: 16 jun 2023
Versión: 5
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.