MFE SCF: EMCP020E EXTRANEOUS DATA IN COMMAND returned when Thin Monitoring parameter ACTION=MESSAGE(MESSAGE) coded.
Resumen: Felaktig verifiering av MEDDELANDE-parametern med PARM_VERIFY=YES
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
When the PARM_VERIFY=YES parameter is specified in the ResourcePak Base initialization file, the incorrect EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ")" message is displayed.Exempel:
SCF0301I SCF.THN.03.LIST = ACTION=MESSAGE(MESSAGE) SCF0313I SCF.THN.03.LIST=ACTION=MESSAGE(MESSAGE) EMCP010E * EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ) SCF0301I SCF.THN.03.LIST = FREQUENCY=REPEAT SCF0301I SCF.THN.04.LIST = PERCENT=(99,100) SCF0301I SCF.THN.04.LIST = DURATION=60 SCF0301I SCF.THN.04.LIST = ACTION=MESSAGE(MESSAGE) SCF0313I SCF.THN.04.LIST=ACTION=MESSAGE(MESSAGE) EMCP010E * EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ) SCF0301I SCF.THN.04.LIST = FREQUENCY=REPEAT
Causa
Det beror på ett programvaruproblem.
Resolución
Permanent lösning:
- För Mainframe Enablers 8.5 har PTF SF85111 utvecklats för att korrigera problemet. Det går att ladda ner från Dells onlinesupport.
- För Mainframe Enablers 8.4 har PTF SF84158 utvecklats för att korrigera problemet. Det går att ladda ner från Dells onlinesupport.
Información adicional
EMCP020E
ONÖDIGA DATA I KOMMANDO; FOUND: value
Cause
While parsing the input data stream, a syntax error was detected, and extraneous data was found.
Åtgärder
Korrigera indataströmmen.
PTF-hölje – anmärkning:
ONÖDIGA DATA I KOMMANDO; FOUND: value
Cause
While parsing the input data stream, a syntax error was detected, and extraneous data was found.
Åtgärder
Korrigera indataströmmen.
PTF-hölje – anmärkning:
++PTF(SF85111) REWORK(2022038) . ++VER(Z038) FMID(SSCF850) PRE( SF85002 SF85042 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * USERS AFFECTED: Users of the THN Monitor * PROBLEM DESCRIPTION: Incorrect verification of the MESSAGE * parameter with PARM_VERIFY=YES * DESCRIPTION DETAIL: * * When the PARM_VERIFY=YES parameter is specified in the SCF * initialization file, the incorrect * EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ) * message is displayed. * * PROBLEM RESOLUTION: * * The code has been updated to correctly verify syntax of the * MESSAGE parameter. * * MODULES: ESFINI * SCFLIND * * ------------------------------------------------------------ * SF85111 7 Feb 2022 15:15:32 * ------------------------------------------------------------