BigSwitch ZTD does not complete when using OS10 as p-network switch.

Résumé: The DellEMC OS10 based switch as the p-network switch for a BigSwitch Fabric. The BCF or BMF switches may not fully boot and connect to the controller in a switchlight operating system. The boot stops at the ZTD discovery. ...

Cet article concerne Cet article ne concerne pas Cet article n’est associé à aucun produit spécifique. Toutes les versions du produit ne sont pas identifiées dans cet article.

Symptômes

 

The controller and switches can ping each other IPv6 link local address. However, the process still does not fully complete. This can occur when the IPv6 packet crosses between switches such as the topology below. 

P-Switch-Topology


 

 

 

 

Cause

The MLD snooping will not forward the ipv6 ND packets across the port-channel between switches. 

Résolution

To resolve this issue the following commands globally on both switches:

OS10(config)# no ip igmp snooping enable

OS10(config)# no ipv6 mld snooping enable

Dell EMC OS10 has IGMP snooping and IPv6 MLD snooping enabled by default. This can result in the IPv6 discovery frames from Switchlight to the controller to be intercepted between switches.

Produits concernés

PowerSwitch S3048-ON, Dell EMC BSN Controller Node, Dell EMC BSN Controller VM, PowerSwitch S4048T-ON, PowerSwitch S4148F-ON/S4148T-ON/S4148FE-ON, PowerSwitch Z9332F-ON, SmartFabric OS10 Software
Propriétés de l’article
Numéro d’article: 000132960
Type d’article: Solution
Dernière modification: 11 oct. 2023
Version:  5
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.