DSA-2022-304: Dell Connectrix (Brocade) Security Update for EZswitch Vulnerability
Résumé: Dell Connectrix (Brocade) remediation is available for an EZswitch vulnerability in Brocade Fabric OS (FOS) software that may be exploited by malicious users to compromise the affected system. ...
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Impact
Critical
Détails
| Third-party Component | CVE | More information |
| Connectrix (Brocade) FOS | CVE-2022-33186 | See NVD (http://nvd.nist.gov/ |
| Third-party Component | CVE | More information |
| Connectrix (Brocade) FOS | CVE-2022-33186 | See NVD (http://nvd.nist.gov/ |
Produits concernés et mesure corrective
| CVE Addressed | Product | Affected Versions | Updated Versions | Link to Update |
| CVE-2022-33186 | Connectrix (Brocade) FOS | Brocade Fabric OS (FOS) v9.1.1, v9.0.1e, v8.2.3c, and v7.4.2j and earlier | v9.1.1_01 v9.0.1e1, v8.2.3c1 v7.4.2j1 |
Link to update |
| CVE Addressed | Product | Affected Versions | Updated Versions | Link to Update |
| CVE-2022-33186 | Connectrix (Brocade) FOS | Brocade Fabric OS (FOS) v9.1.1, v9.0.1e, v8.2.3c, and v7.4.2j and earlier | v9.1.1_01 v9.0.1e1, v8.2.3c1 v7.4.2j1 |
Link to update |
Solutions de contournement et mesures d’atténuation
To remove any exposure to this vulnerability, Brocade Fabric OS switch administrators must disable EZServer support or upgrade to a version of FOS that has the EZServer module removed.
Disabling EZServer is accomplished by using the CLI command "configurechassis." Disabling the EZServer in the switch configuration prevents any exposure to this vulnerability. This option is only available on FOS versions v8.1.0b and later. Customers running on older versions of FOS, including v7.4.2j, do not have this option and must upgrade to FOS v7.4.2j1 to protect their switches.
Customers that elect to upgrade their FOS version can obtain a patch with the EZServer module removed:
- FOS v9.1.1_01 and higher versions
- FOS v9.0.1e1 and higher versions
- FOS v8.2.3c1 and higher versions
- FOS v7.4.2j1 and higher versions
Example showing how to disable the EZServer module:
brocadeswitch:admin> configurechassis Configure... cfgload attributes (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no] webtools attributes (yes, y, no, n): [no] y ... Login Session Timeout (in secs): (60..432000) [7200] EZserver Enabled (yes, y, no, n): [yes] no ... brocadeswitch:admin >
Notes:
The following actions reenable EZServer on Fabric OS versions that do not have the EZServer module entirely removed:
- firmwarecleaninstall
- config removall
- configdefault
- factory reset
Historique des révisions
| Revision | Date | Description |
| 1.0 | 2022-11-09 | Initial Release |
| 2.0 | 2023-02-14 | Corrected "Affected Product" section under "Article Properties." |
Informations connexes
Mention légale
Produits concernés
Connectrix, Connectrix, Connectrix B-Series, Connectrix B-Series, Brocade 5100, Brocade 6520, Brocade G620, Brocade M6505, Connectrix, Connectrix B-Series Fabric OS 9.X, Connectrix B-Series Software, Connectrix DS-300B, Connectrix DS-6505B
, Connectrix DS-6510B, Connectrix DS-6620B, Connectrix DS-6620B-V2, Connectrix DS-6630B, Connectrix DS-6630B-V2, Connectrix DS-7720B, Connectrix DS-7730B, Connectrix ED-DCX6-4B, Connectrix ED-DCX6-8B, Connectrix ED-DCX7-4B, Connectrix ED-DCX7-8B, Connectrix ED-DCX8510-4B, Connectrix ED-DCX8510-8B, Connectrix MP-7800B, Connectrix MP-7810B, Connectrix MP-7840B, Product Security Information
...
Propriétés de l’article
Numéro d’article: 000205092
Type d’article: Dell Security Advisory
Dernière modification: 18 sept. 2025
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.