Data Domain: SRM Discovery Issues with Timed Out Errors
Résumé: The article describes timeout failures during SRM discovery of Data Domain systems. Long polling cycles and TTL expirations are caused by the maxBulkSize value being too large.
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
Discovery issues occur on Data Domain systems. Timeout errors are reported. These same Data Domain systems were discovered earlier without issues. Increasing the timeout to 1200 only cleared the issue for some Dell Data Domain appliances.
The Data Domain collector log shows the following generic errors:
WARNING -- [2023-02-15 10:59:00 MST] -- PollingUnitPollingGroup::waitAtEndOfPollingCycle(): Polling group 300.EMC-DATA-DOMAIN-BOOST.EMC-DATA-DOMAIN-CIFS.EMC-DATA-DOMAIN-DISK.EMC-DATA-DOMAIN-ENV.EMC-DATA-DOMAIN-FS.GENERIC-INTERFACES.GENERIC-HOST-RESOURCES-PROCESSOR.GENERIC-HOST-RESOURCES-STORAGE.EMC-DATA-DOMAIN-MTREE.EMC-DATA-DOMAIN-NFS.EMC-DATA-DOMAIN-QUOTA.EMC-DATA-DOMAIN-REPLICATION.GENERIC-SYSUPTIME.EMC-DATA-DOMAIN-SYSTEM.EMC-DATA-DOMAIN-VTL is taking too long: Completed in 425081ms. Skipping next polling cycle. 174919ms until next polling, at timestamp: 1676484115000 WARNING -- [2023-02-15 11:01:56 MST] -- PollingUnitTable::closeSession(): Interrupted session on xxx-xxxxxx.xx.xx.org:161 : Time to live has expired.
Cause
The default maxBulkSize of 50 was causing discovery timedout errors.
Résolution
In the incident that generated this KB article, reducing the maxBulkSize value cleared the discovery issue.
Set the maxBulkSize value to a lower number, such as 15.

Propriétés de l’article
Numéro d’article: 000210196
Type d’article: Solution
Dernière modification: 17 juil. 2026
Version: 5
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.