Avamar: ADS Gen5: Event code=52804 A memory device error occurred

Résumé: Event code=52804, A memory device error occurred

Cet article concerne Cet article ne concerne pas Cet article n’est associé à aucun produit spécifique. Toutes les versions du produit ne sont pas identifiées dans cet article.

Symptômes

A message similar to the following may be displayed in the MCCLI event show, the Avamar User Interface (AUI) events page, or in the /var/log/messages file:

EventID: 52804 A memory device error occurred. The system may continue to function as normal (except for a multibit error). Replace the memory module identified in the message during the system's next scheduled maintenance. Clear the memory error on multibit ECC error. The memory device status and location are provided

Cause

Predictive DIMM failure.

Résolution

Log in to the affected node and run the following command:

Omreport chassis memory
 

A failed memory slot similar to the following may be returned:

Index          : 3
Status         : Critical
Connector Name : A4
Type           : DDR4 - Synchronous Registered (Buffered)
Size           : 16384  MB
 

Example of output for a normal memory slot:

Index          : 6
Status         : Ok
Connector Name : B1
Type           : DDR4 - Synchronous Registered (Buffered)
Size           : 16384  MB
 

An unoccupied memory slot still has a connector name. Example of output for an unoccupied memory slot:

Index          :
Status         : Unknown
Connector Name : A7
Type           : [Not Occupied]
Size           :
 
 

There are several Error Codes that make up this Symptom Code. Most of them require no action. The following event codes do require action:
(Notice that the error codes may be designated as either Event Code, MessageID, or Code)

 
Error code Description Recommended Action
MEM0001 Multi-bit memory errors are detected on the memory device at location arg1.

Immediately replace the DIMM.

 

MEM0702 System detected and corrected memory errors

Reboot the system to enable potential memory self-healing.

 

MEM9072 The system memory has uncorrectable multi-bit memory errors in the nonexecution path of a memory device at the location arg1.

Immediately replace the DIMM.

 

MEM0702 
"Correctable memory error rate exceeded for DIMM_XX."
Immediately replace the DIMM.
 

If the recommended action above is to replace the DIMM, use the Connector Name to specify which slot should be replaced. There is no need to replace multiple slots, as was the case in Gen4t.

Produits concernés

Avamar, Avamar Server
Propriétés de l’article
Numéro d’article: 000214852
Type d’article: Solution
Dernière modification: 03 août 2026
Version:  9
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.