PowerStore: When storage networks scaled to 50 (or more), PowerStoreOS upgrades may fail with "Uninitialized" ports

Riepilogo: When storage networks are scaled to a substantial number of NVMe/TCP ports (for example, greater than 50), with Auto Discovery of CDC option enabled, CDC connection state on all NVMe/TCP ports may appear Uninitialized and subsequent PowerStoreOS upgrades may fail. ...

Questo articolo si applica a Questo articolo non si applica a Questo articolo non è legato a un prodotto specifico. Non tutte le versioni del prodotto sono identificate in questo articolo.

Sintomi

Example:
CDC connection states on all NVMe/TCP ports in the affected PowerStore cluster appear 'Uninitialized' when the number of NVMe/TCP ports is greater than 50.
image.png

Causa

When storage networks are scaled to a substantial number of NVMe/TCP ports (for example, greater than 50), with Auto Discovery of CDC option enabled, the PowerStoreOS upgrade process may lead to a resource exhaustion that may result in failure of subsequent upgrades.

Risoluzione

Resolution

Upgrade to PowerStoreOS version 3.2 or later, which includes the fix for this issue (for subsequent upgrades).
 

Workaround

Perform the steps below to avoid this issue during the upgrade to PowerStoreOS version 3.2:​​​​​​
  1. Before the upgrade starts, disable the 'Auto Discovery of CDC' option. Choose one of the following two methods:
    • PowerStore Manager user interface (UI): Settings > Network IPs > STORAGE
      image.png
      image.png
    • PSTCLI: 
      network -id XXXX set -nvme_discovery_mode Auto_Discovery_Disabled
      or
      network -name XXXX set -nvme_discovery_mode Auto_Discovery_Disabled
  2. After the upgrade, reenable the Auto Discovery of CDC option using the UI or PSTCLI (see pstcli network set -h for options).
    Note: This step is optional. Follow this step only when planning to use the Auto Discovery of CDC option following the upgrade to PowerStoreOS version 3.2.

Informazioni aggiuntive

Disabling Automatic Discovery disables mDNS. No attempt will be made to register with a CDC if one exists. This is a compatibility mode for environments that are compliant with NVMe-oF 1.1.