Dell Unity: PUHC non riuscito per ERROR_CODE=platform::check_for_hardware_faults_2
Riepilogo: Dell Unity PUHC (Pre Upgrade Health Check) non riuscito per ERROR_CODE=platform::check_for_hardware_faults_2
Questo articolo si applica a
Questo articolo non si applica a
Questo articolo non è legato a un prodotto specifico.
Non tutte le versioni del prodotto sono identificate in questo articolo.
Sintomi
Dell Unity PUHC non riuscito per ERROR_CODE = platform::check_for_hardware_faults_2
One or more errors have occurred. Follow the instructions provided to correct the problem and try again. Upgrade cannot proceed. -------------------------------------Errors------------------------------------- Platform: Check for hardware faults A power supply hardware fault (AC Power Loss) detected on: spb Action : Check you power cables. If correct, contact your online portal for replacement instructions. ERROR_CODE=platform::check_for_hardware_faults_2|Error|spb Platform: Check for enclosure faults A fault in the DPE enclosure was detected Action : Contact your online portal for corrective instructions. ERROR_CODE=platform::check_for_enclosure_faults_2|Error| --------------------------------------------------------------------------------
Causa
Come parte del controllo integrità preliminare all'aggiornamento, vengono esaminati gli stati hardware dei seguenti componenti:Alimentatori
Battery Backup Unit
Ventole
DPE
DAE
L'errore platform::check_for_hardware_faults_2 indica che è stato rilevato un guasto nell'enclosure DPE.
Nell'esempio precedente il problema specifico è un guasto hardware dell'alimentatore (perdita di alimentazione CA) rilevato su: spb
Battery Backup Unit
Ventole
DPE
DAE
L'errore platform::check_for_hardware_faults_2 indica che è stato rilevato un guasto nell'enclosure DPE.
Nell'esempio precedente il problema specifico è un guasto hardware dell'alimentatore (perdita di alimentazione CA) rilevato su: spb
Risoluzione
Controllare gli avvisi e le raccolte di dati della GUI per individuare eventuali guasti hardware e sostituirli in base alle esigenze.
In questo esempio, l'alimentatore DPE B0 non riceve alimentazione ed è pronto per la sostituzione.
TRiiAGE_full_SPlogs.txt
A 04/29/24 09:53:25.471 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:28.451 Bus0 Enc0 PowB 1678006 [ERROR] System: Power Supply is Faulted (GenFlt/AcFail ). B 04/29/24 09:53:28.458 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:48.597 DGSSP 1 [INFO] System: 04/29/2024 09:53:07 | BMC Power Supply Status | PS1_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 A 04/29/24 09:54:15.409 DGSSP 1 [INFO] System: 04/29/2024 09:53:06 | BMC Power Supply Status | PSB_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 B 04/29/24 09:54:16.285 Health 601f4 [CRIT] User: Power supply DPE Power Supply B0 is not receiving power B 04/29/24 09:54:16.465 Health 60516 [ERROR] User: System dsus017d2-un32 has experienced one or more problems that have had a major impact.
SPB_fbecli_exe_ccollectall.txt
---------------------------------------------------------------- FBECLI> sptime: Current Time: 05/16/24 10:08:26.283 SP TimeStamp: 14267394886ms ---------------------------------------------------------------- FBECLI> spstat: SP B [Passive SP] PEER SP: PRESENT HW Cache Status: DEGRADED Reason: PS Physical memory: SPA(65536 MB), SPB(65536 MB) DPE-MIRANDA 0 (Bus 0, Pos 0) -OK EnclFaultLedStatus: ON EnclFaultLedReason: PS Fault PS A B OK (0214) FLT (0214)
Prodotti interessati
Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Family, Dell EMC Unity Hybrid, Dell Unity Operating Environment (OE)Proprietà dell'articolo
Numero articolo: 000228125
Tipo di articolo: Solution
Ultima modifica: 29 lug 2025
Versione: 4
Trova risposta alle tue domande dagli altri utenti Dell
Support Services
Verifica che il dispositivo sia coperto dai Servizi di supporto.