PPDM: Distribution av vSphere-installationspaketet misslyckas med felkoden "ABV0032"

Riepilogo: På Broadcom ESXi-värden misslyckas distribution eller uppdatering av vSphere Installation Bundle (VIB) med felkoden ABV0032.

Questo articolo si applica a Questo articolo non si applica a Questo articolo non è legato a un prodotto specifico. Non tutte le versioni del prodotto sono identificate in questo articolo.

Sintomi

Vid installation eller uppdatering av PowerProtect Data Manager (PPDM) vSphere Installation Bundle for Transparent Snapshot Data Mover (TSDM) misslyckas konfigurationsjobbet med felmeddelanden som liknar följande:

ABV0032: VM Direct Engine is unable to configure protection for the host "ESXi Host" on vCenter "VCenterName"

 

Under avsnittet med felinformation rapporteras ett felmeddelande som liknar följande:

Unable to install vSphere Installation Bundle on host "ESXi Host". vCenter task is failed with /usr/sbin/esxupdate returned with exit status: 15
 

 

Jobbfel i PPDM-gränssnittet

 

Causa

På vCenter-servern krävs lagringsgenomsökning. Annars rapporteras felmeddelanden liknande följande i loggfilen "esxupdate" på Broadcom ESXi-värden:

 

esxupdate: 9408626: Transaction: INFO: Final list of VIBs being installed: DEL_bootbank_tsdm_19. 18. 0. 3-10EM. 703. 0.0.18644231
esxupdate: 9408626: imageprofile: INFO: Adding VIB DEL_bootbank_tsdm_19. 18.0.3-10EM. 703. 0.0.18644231 to ImageProfile (Updated) ESXi-7. OU3n-21930508-standard
esxupdate: 9408626: esxupdate: ERROR: An esxupdate error exception was caught:
esxupdate: 9408626: esxupdate: ERROR: Traceback (most recent call last) :
File "/lib64/python3.8/site-packages/vmware/esximage/Utils/HostInfo.py", line 217, in getFileSystems
return runCli ( ['storage', 'filesystem', 'list' ], True)
File "/lib64/python3.8/site-packages/esxutils.py", line 220, in runCli
esxupdate: 9408626: esxupdate: ERROR: esxutils. EsxcliError: Errors:
esxupdate: 9408626: esxupdate: ERROR: Error getting data for filesystem on '/vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx': Cannot open volume: /vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx, skipping.
esxupdate: 9408626: esxupdate: ERROR:
ERROR:
esxupdate: 9408626: esxupdate:
esxupdate: 9408626: esxupdate: ERROR: During handling of the above exception, another exception occurred:
esxupdate: 9408626: esxupdate: ERROR:
esxupdate: 9408626: esxupdate: ERROR: Traceback (most recent call last) :
File "/usr/sbin/esxupdate", line 222, in main
cmd. Run ()
File "/lib64/python3.8/site-packages/vmware/esx5update/Cmdline.py", line 153, in Run
File "/lib64/python3.8/site-packages/vmware/esximage/Transaction.py", line 852, in InstallVibsFromSources
inst, removed, exitstate = self. installVibs (curprofile,
File "/lib64/python3.8/site-packages/vmware/esximage/Transaction.py", line 1098, in installVibs
exitstate = self. validateAndInstallProfile(
File "/lib64/python3.8/site-packages/vmware/esximage/Transaction.py", line 1267, in validateAndInstallProfile
resVibCache = ReservedVibCache ()
File "/lib64/python3.8/site-packages/vmware/esximage/ImageManager/HostSeeding.py", line 995, in init
self. loadCachedVibs ()
File "/lib64/python3.8/site-packages/vmware/esximage/ImageManager/HostSeeding.py", line 1032, in loadCachedVibs
for fsPath in HostInfo.GetVmfslFileSystems () :
File "/lib64/python3. 8/site-packages/vmware/esximage/Utils/HostInfo.py", line 260, in GetVmfslFileSystems
return [fs['Mount Point'] for fs in getFileSystems ()
File "/lib64/python3.8/site-packages/vmware/esximage/Utils/HostInfo.py", line 220, in getFileSystems
raise Errors. InstallationError (e, None, msg)
esxupdate: 9408626: esxupdate: ERROR: vmware. esximage. Errors. InstallationError: Failed to query file system stats: Errors:
esxupdate: 9408626: esxupdate: ERROR: Error getting data for filesystem on '/vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx': Cannot open volume: /vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx, skipping.
esxupdate: 9408626: esxupdate: ERROR:
esxupdate: 9408626: esxupdate: DEBUG: <<<

Risoluzione

För att lösa det här problemet krävs en ny genomsökning av lagringsenheter.

 

Följande kunskapsbasartikel från Broadcom innehåller anvisningar om hur du utför lagringsgenomsökning [Extern länk kontrollerades senast den 11 mars 2025]:

 Utföra en ny genomsökning av lagringen på en ESXi-värd 

 

Prodotti interessati

PowerProtect Data Manager, PowerProtect Data Manager Essentials

Prodotti

PowerProtect Data Manager Software
Proprietà dell'articolo
Numero articolo: 000293446
Tipo di articolo: Solution
Ultima modifica: 10 set 2025
Versione:  3
Trova risposta alle tue domande dagli altri utenti Dell
Support Services
Verifica che il dispositivo sia coperto dai Servizi di supporto.