[Isilon] Node fails to boot or reimage to OneFS v8.1.x after Back-End Conversion
요약: Customer wanted to convert the IB back-end network to ETH. The conversion procedure only exists on v8.2 code. After the conversion, the customer wanted to revert the new nodes back to v8.1 so a USB re-image took place. The re-image process failed. ...
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
After an IB-to-ETH back-end network conversion procedure (an internal DELL EMC PS service), the attempted re-image of a node to v8.1.x failed with the following error:
Verifying hardware configuration...
No backend network devices detected for LNI.xml creation. Actual NIC type: 40 GigE, Expected: Infiniband
Verify Hardware exited with an error.
Aborting boot.
원인
Nodes that were built with backend IB interfaces contain a special type of backend NIC called a VPI card. This NIC is capable of both InfiniBand and Ethernet networking. The backend conversion process introduced in OneFS 8.2 allows the card to be switched from IB mode to Ethernet mode, enabling cluster migration to an Ethernet backend network. Prior versions of OneFS do not 'understand' that this card can operate in either mode, and when this card is detected in those versions it is presumed to be an InfiniBand card, causing the hardware check to fail since the configured backend type (Ethernet) does not match the detected backend type ('InfiniBand').
해결
Nodes with VPI backend NICs operating in Ethernet mode are only supported in OneFS v8.2 and newer, and cannot be downgraded to an older version. Once OneFS 8.2 or newer is reinstalled, the node will function normally.
해당 제품
Isilon제품
Isilon, Isilon A200, Isilon F800, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600, PowerScale OneFS문서 속성
문서 번호: 000173413