DSS7500: Dvojitá chyba a jak vynutit online disk

요약: Tento článek se zabývá dvojitou chybou DSS7500 a jak vynutit připojení online disku.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

증상

Konfigurace DSS7500:
  • Karta RAID SI9361-8i
  • Vyměněný disk28 
  • Disk40 hot spare se obnovuje.
  • Disk22 je ve stavu offline
  • Opětovné vytvoření Disk40 se nezdařilo kvůli chybě zdrojového ovladače, selhaly dva pevné disky a selhal virtuální disk.
  1. Vzdálená kontrola disku 22 HD offline, disk28 pevného disku nenakonfigurovaného jako funkční (chybí)
  2. Protokol karty RAID kontroluje přechod VD0 do omezeného režimu, když je disk 22 offline a VD0 selhal.
Obrázek 1: Informace o řadiči RAID
Informace o řadiči RAID
 
1034450: 23-10-28,08:06:02 BG Work:CopyBack progress on PD b4(e0x64/s32) is 99.25%(116579s)
1034451: 23-10-28,08:53:56 Info:CopyBack complete on PD b4(e0x64/s32) from PD ba(e0x64/s40)
1034452: 23-10-28,08:53:57 Info:State change on PD b4(e0x64/s32) from COPYBACK(20) to ONLINE(18)
1034453: 23-10-28,08:53:57 Info:Global Hot Spare created on PD ba(e0x64/s40) (global,rev)
1034454: 23-10-28,08:53:57 Info:State change on PD ba(e0x64/s40) from ONLINE(18) to HOT SPARE(2)
1034459: 23-10-31,15:05:18 Info:State change on PD a0(e0x65/s28) from ONLINE(18) to OFFLINE(10)
1034460: 23-10-31,15:05:18 Info:State change on VD 00/0 from OPTIMAL(3) to DEGRADED(2)
1034461: 23-10-31,15:05:18 CRITICAL:VD 00/0 is now DEGRADED.
1034475: 23-10-31,15:15:02 Info:Inserted: PD a0(e0x65/s28)
1034476: 23-10-31,15:15:02 Info:Inserted: PD a0(e0x65/s28) Info: enclPd=65, scsiType=0, portMap=00, sasAddr=5f01faf0fd32821c,0000000000000000
1034477: 23-10-31,15:15:02 Info:PD a0(e0x65/s28) Inquiry info: Info- ATA  TOSHIBA MG07ACA1 T0A0CFF9SG 11 TB
1034478: 23-10-31,15:15:02 Info:State change on PD a0(e0x65/s28) from UNCONFIGURED_BAD(1) to UNCONFIGURED_GOOD(0)
1034481: 23-10-31,16:29:22 BG Work:Rebuild progress on PD ba(e0x64/s40) is 0.99%(5040s)
…
1034534: 23-11-01,21:31:58 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 88 00 00 00 00 01 6e 67 88 98 00 00 00 08 00 00, Sense: 72 03 11 00 00 00 00 0C 00 0A 80 00 00 00 00 01 6E 67 88 98
1034585: 23-11-02,07:27:28 BG Work:Rebuild progress on PD ba(e0x64/s40) is 82.17%(145326s)
1034586: 23-11-02,07:48:59 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 88 00 00 00 00 03 c6 b3 20 00 00 00 02 00 00 00, Sense: 72 03 11 00 00 00 00 0C 00 0A 80 00 00 00 00 03 C6 B3 22 60
1034587: 23-11-02,07:48:59 Info:Error on PD 98(e0x65/s22) (Error 02)
1034588: 23-11-02,07:48:59 Info:State change on PD 98(e0x65/s22) from ONLINE(18) to SHIELD(90)
1034589: 23-11-02,07:48:59 Info:State change on VD 00/0 from DEGRADED(2) to OFFLINE(0)
1034590: 23-11-02,07:48:59 FATAL:Controller cache pinned for missing or offline VD 00/0
1034591: 23-11-02,07:48:59 FATAL:VD 00/0 is now OFFLINE
1034592: 23-11-02,07:48:59 Info:Error on PD 98(e0x65/s22) (Error 02)
1034593: 23-11-02,07:48:59 CRITICAL:Rebuild failed on PD by(e0x64/s40) due to source drive error
1034594: 23-11-02,07:48:59 Info:State change on PD ba(e0x64/s40) from REBUILD(14) to HOT SPARE(2)
1034597: 23-11-02,07:49:02 WARNING:PD 98(e0x65/s22) Path 5f01faf0fd328216  reset (Type 03)
1034598: 23-11-02,07:49:04 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 28 00 00 00 00 00 00 00 04 00, Sense: 70 00 06 00 00 00 00 0A 00 00 00 00 29 00 00 00 00 00
1034599: 23-11-02,07:49:04 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 00 00 00 00 00 00, Sense: 70 00 02 00 00 00 00 0A 00 00 00 00 04 02 00 00 00 00
1034601: 23-11-02,07:55:14 Info:Diagnostics passed for PD 98(e0x65/s22)
1034602: 23-11-02,07:55:14 Info:State change on PD 98(e0x65/s22) from SHIELD(90) to OFFLINE(10)

원인

Viz níže

해결

  1. Pokuste se vynutit online připojení posledního offline disku. Pokud disk přejde do režimu online, virtuální disk se může obnovit do sníženého režimu.
  2. V tomto případě online disk22 v řadiči RAID Konfigurační utilita AVAGO MegaRAID 9361-8i HII (Human Interface Infrastructure) Níže jsou uvedeny kroky:
    1. Restartujte server. Když je systém spuštěn, stiskněte<klávesu F2>a přejděte do nastavení systému.
    2. Kliknutím na Nastavení zařízení vstoupíte do nabídky Správa řadiče AVAGO MegaRAID 9361-8i. K pohybu použijte klávesy se šipkami nebo myš.
Obrázek 2: Stav RAID 50 Offline
Kontrola stavu pole RAID 50: Offline
 
Obrázek 3: Port disku 0–3:01:28 Pevný disk nenakonfigurovaný, funkční
Port disku 0–3:01:28 Pevný disk nenakonfigurovaný, funkční
 
Obrázek 4: Chybí port disku 0–3:01:28
Chybí port disku 0–3:01:28
 
Obrázek 5: Port disku 0–3:01:22 OfflinePort disku 0 – 3:01:22 Pevný disk Offline
 
Obrázek 6: Port disku 0–3:01:22 Offline
Pohled na správu diskové jednotky Port jednotky 0–3:01:22 Offline
  1. Vyberte operaci > "Drive Port 0 - 3:01:22 hard drive". >Umístění disku do režimu online > Potvrďte, že je operace v pořádku.
Obrázek 7: Umístěte disk online
Umístěte disk online
  1. Zkontrolujte, zda se stav pole RAID 50 obnoví na Degraded.
Obrázek 8: Snížený stav pole RAID 50. 
Stav pole RAID 50 se obnoví na Degraded
  1. V softwaru pro správu řadiče RAID AVAGO MegaRAID 9361-8i zkontrolujte, zda je disk22 online a zda probíhá obnova disk40.
Obrázek 9: Disk22 je online a disk40 se obnovuje.
Disk22 je online a disk40 se obnovuje.
  1. Pokud je nutné disk vyměnit, zkontrolujte informace o slotu disku.
Obrázek 10: Informace o slotu disku
Informace o slotu disku