Dell Unity: Fejlkode til redningsårsag til storageprocessor: 0x1b01

Sammendrag: En Unity Storage Processor (SP) fejler og skifter til servicetilstand med fejlkode 0xb01, 6913 eller 1:1678040.

Denne artikkelen gjelder for Denne artikkelen gjelder ikke for Denne artikkelen er ikke knyttet til noe bestemt produkt. Det er ikke produktversjonene som identifiseres i denne artikkelen.

Symptomer

En eller begge storageprocessorer kan være i servicetilstand med følgende redningsårsag:

======== Now executing basic state ========
* System Serial Number is: APM00172106812
* System Friendly Host Name is: (none)
* Current Software version: Unable to determine full software version.
* Unisphere IP address(es): 10.90.24.250 fe80::260:1600:47e0:2a26
* FIPS mode: Disabled
* Boot Mode: Rescue Mode
* Post Faults:  0x0000
* Backend Faults:       0x0000
* Boot Faults:  0x1b00
* Rescue Reason:        0x1b01
* Rescue reason for code 0x1b01 - There is a problem with the system software on this Storage Processor. To attempt to correct this problem, first run Data Collection, and then try the following in order: Check all cables, reboot each SP, and reimage each Storage Processor (SP). If this does not resolve the issue, contact your service provider.

 

Følgende yderligere fejlkoder og meddelelser kan også genereres under dette problem:

  • ERROR" "1:1678040
  • Storage Processor SP B has faulted and is in Service Mode with reason code 6913
  • Storage Processor SP A has faulted and is in Service Mode with reason code 6913
  • SERVICE_ERR_0x1b01

Årsak

Ikonet sep -modulet i tjenesten SAFE forårsager typisk dette problem. Du kan dokumentere dette ved at gennemgå følgende logplaceringer:.

 

/EMC/C4Core/log/start_c4.log:

Wed Sep 27 19:00:53 2017: start_c4.pl:  *****************************************************
Wed Sep 27 19:00:53 2017: start_c4.pl:  * Error Detected SP Degraded Mode after sep started.
Wed Sep 27 19:00:53 2017: start_c4.pl:  * Incrementing SOFTWARE boot counter
Wed Sep 27 19:00:53 2017: start_c4.pl:  * Driver rrchc code: 0x1b01
Wed Sep 27 19:00:53 2017: start_c4.pl:  *****************************************************

 

/var/log/boot.out:

2017-09-29 18:36:31.598 ===== bringup_backend =====
2017-09-29 18:36:32.105 Loading mirror driver
2017-09-29 18:36:37.787 read degraded mode bit from nvram and check if sep is degraded
2017-09-29 18:36:37.996 MCR database degraded mode:  00000001
2017-09-29 18:36:38.332 1
2017-09-29 18:36:39.064 =================================================================
2017-09-29 18:36:39.068 ===   ***  Going into service mode because of a fault  ***    ===
2017-09-29 18:36:39.072 =================================================================
2017-09-29 18:36:39.082 === When escalating to platform services, please make sure to ===
2017-09-29 18:36:39.086 === include the messages ABOVE this notice. You can ignore    ===
2017-09-29 18:36:39.090 === any errors below.                                         ===
2017-09-29 18:36:39.094 =================================================================

Oppløsning

Kontakt Dells tekniske support eller din autoriserede servicerepræsentant, og oplys dette artikel-id i Dell Knowledge Base.

Berørte produkter