PowerFlex: QueryChangedDiskAreas API Returns Incorrect Sectors

Sammendrag: QueryChangedDiskAreas API returns incorrect sectors after extending virtual machine VMDK file with Changed Block Tracking (CBT) enabled in ESXi 8.0u2.

Denne artikkelen gjelder for Denne artikkelen gjelder ikke for Denne artikkelen er ikke knyttet til noe bestemt produkt. Det er ikke produktversjonene som identifiseres i denne artikkelen.

Symptomer

CBT's QueryChangedDiskAreas may lose some data changed on the disk after disk is hot-extended. It happens on ESXi 8.0u2 and VMC 1.24.1.

 

Årsak

There is an issue in the QueryChangedDisk Areas API.

 

Oppløsning

In order to resolve this issue, update to ESXi 8.0 Update 2b or newer.

Workaround

  1. Reset CBT after disk is hot-extended. Then, the user must take a full backup immediately.
    It does not fix existing backups, but it ensures that the new ones are good. Follow these steps to reset CBT Resetting Changed Block Tracking for VMware vSphere virtual machines (External Link)

  2. Or, the user extends the disk in offline.

 

Tilleggsinformasjon

Berørte produkter

VxBlock and Vblock Systems, PowerFlex rack, PowerFlex Appliance, PowerFlex custom node
Artikkelegenskaper
Artikkelnummer: 000223945
Artikkeltype: Solution
Sist endret: 30 des. 2025
Versjon:  2
Få svar på spørsmålene dine fra andre Dell-brukere
Støttetjenester
Sjekk om enheten din er dekket av støttetjenestene.