NetWorker: v9.0 VMware-töitä ei voi kloonata CloudBoost-laitteeseen
Summary: VMware vProxyn tallennusjoukkojen kloonaus CloudBoostiin epäonnistuu. Virheelliset tallennusjoukon tunnukset, ei työkohteita, virhe: pooli tuetuilla solmuilla; Syy: solmuversio 9.1.
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
VMware-varmuuskopioiden (vProxy-varmuuskopiointi) tallennusjoukkojen kloonaus CloudBoost-laitteeseen epäonnistuu.
mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid <SSID> mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. . mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list. mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS! mm/dd/yyyy hh:mm:ss meridiem No valid backend job mm/dd/yyyy hh:mm:ss meridiem [ORIGINAL REQUESTED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/; mm/dd/yyyy hh:mm:ss meridiem [CLONE SKIPPED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>; mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1 mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.
Virheen daemon-lokin < tarkastelu virheen hetkellä kk/pp/vv hh:mm:ss meridiem> löytää viestin:
71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>' 165718 mm/dd/yyyy hh:mm:ss meridiem 5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>. 71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '. 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed 89017 mm/dd/yyyy hh:mm:ss meridiem 1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
Cause
Pyydä parannusta. Tunnettu ongelma: NW-I-404: NetWorker: Kloonaus vProxy-tallennusjoukoilla CloudBoost-laitteeseen.
Resolution
Tuotehallinta tutkii parannuspyyntöä. Pyyntöä käsitellään edelleen. Ota yhteyttä asiakastukikeskukseen saadaksesi apua ja mainitse tämän artikkelin numero.
TILAPÄISRATKAISU: Kun käytössä on NetWorker 9.0.1 tai uudempi tietovyöhyke, määritä ulkoinen tallennussolmu. Katso NetWorker 9.1 CloudBoost 2.1 Integration Guide -oppaan osasta NetWorker 9.1: Laitteen määrittäminen käyttämällä ulkoista tallennussolmua CloudBoostia varten".
TILAPÄISRATKAISU: Kun käytössä on NetWorker 9.0.1 tai uudempi tietovyöhyke, määritä ulkoinen tallennussolmu. Katso NetWorker 9.1 CloudBoost 2.1 Integration Guide -oppaan osasta NetWorker 9.1: Laitteen määrittäminen käyttämällä ulkoista tallennussolmua CloudBoostia varten".
Produse afectate
Cloud Backup & Protection, NetWorkerProprietăți articol
Article Number: 000065416
Article Type: Solution
Ultima modificare: 04 Dec 2025
Version: 5
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.