NetWorker: v9.0 Kan ikke klone VMware-jobber til CloudBoost-enheten

Summary: Kloning av VMware vProxy-lagringssett til CloudBoost mislykkes. Ugyldige lagringssett-ID-er, ingen arbeidselementer, feil: utvalg med noder som ikke støttes; Årsak: Node versjon 9.1.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

 

Kloning av VMware-sikkerhetskopier (vProxy-sikkerhetskopiering) av lagringssett til en CloudBoost-enhet mislykkes.

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

Gjennomgang av daemon loggen på det tidspunktet <mm / dd / yyyy hh:mm: ss meridiem> av feilen finner meldingen:

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Cause

Forespørsel om forbedring. Kjent problem: NW-I-404: NetWorker: Kloning av vProxy-lagringssett til et CloudBoost-apparat.

Resolution

Product Management undersøker denne forespørselen om forbedring. Forespørselen pågår fortsatt. Kontakt kundestøttesenteret for å få hjelp og oppgi dette artikkelnummeret.

OMGÅ: Med en NetWorker 9.0.1-datasone eller nyere kan du konfigurere en ekstern lagringsnode, se "NetWorker 9.1 CloudBoost 2.1 Integration Guide" i delen "NetWorker 9.1: Konfigurere en enhet ved hjelp av en ekstern lagringsnode for CloudBoost".

Produse afectate

Cloud Backup & Protection, NetWorker
Proprietăți articol
Article Number: 000065416
Article Type: Solution
Ultima modificare: 04 Dec 2025
Version:  5
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.