MHC Azure Stack:角色 OEM 的 OEM 类型 FirmwareCheckHealth 引发异常
Summary: 角色 OEM 的 FirmwareCheckHealth 类型引发异常:Error running Test-OEMFirmwareHealth iDRAC has Critical Major faults could not proceed with Firmware update.
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
预检查 OEM 失败错误:
单击 “Download Summary”。
Error.json:
Oem Package Update Perform Oem Extension update. BeforeOEMUpdate Tasks before OEMUpdate. Test Firmware PreUpdate Determine if OEM Firmware should be updated on physical nodes. Firmware Check Health. Check firmware health before update.
单击 “Download Summary”。
Error.json:
Type ‘FirmwareCheckHealth’ of Role ‘OEM’ raised an exception:\n\nError running Test-OEMFirmwareHealth: iDRAC: 10.224.190.3 has Critical Major faults, could not proceed with Firmware update….
Cause
四台服务器中有三台存在内存错误。在继续之前,需要解决这些问题。
The memory health monitor feature has detected a degradation in the DIMM installed in DIMM_A6. Reboot system to initiate self-heal process.
Resolution
要解决此问题,请修复内存错误。
- 使用显示故障内存的 iDRAC 排空节点。
- 排空后,在 PEP PowerShell 窗口中运行以下命令。
get-virtualdisk -cimsession "s-cluster" get-virtualdisk -cimsession "s-cluster" | get-storagejob
- 所有存储作业完成后,从 iDRAC 冷启动服务器
- 验证 DIMM 是否已修复:
The self-heal operation successfully completed at DIMM DIMM_A6.
- 在 Azure Stack 窗口中,启动节点。
- 在 Azure Stack 窗口中,恢复节点。
Produse afectate
Integrated System for Microsoft Azure Stack Hub, Integrated System for Microsoft Azure Stack Hub 14GProprietăți articol
Article Number: 000200301
Article Type: Solution
Ultima modificare: 08 Sep 2025
Version: 3
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.