Avamar ADS 第 5 代:事件代码 = 52804 发生内存设备错误

Summary: 事件代码 = 52804,发生内存设备错误

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

MCCLI 事件显示、Avamar 用户界面 (AUI) 事件页面或 /var/log/messages 中可能会显示类似这样的消息:

EventID: 52804 A memory device error occurred. The system may continue to function as normal (except for a multibit error). Replace the memory module identified in the message during the system's next scheduled maintenance. Clear the memory error on multibit ECC error. The memory device status and location are provided

Cause

预测性 DIMM 故障

Resolution

登录到受影响的节点并运行以下命令:

Omreport chassis memory

可能会返回类似于以下内容的故障内存插槽:

Index          : 3
Status         : Critical
Connector Name : A4
Type           : DDR4 - Synchronous Registered (Buffered)
Size           : 16384  MB

正常内存插槽的输出示例:

Index          : 6
Status         : Ok
Connector Name : B1
Type           : DDR4 - Synchronous Registered (Buffered)
Size           : 16384  MB

未占用的内存插槽仍具有连接器名称。未占用内存插槽的输出示例:

Index          :
Status         : Unknown
Connector Name : A7
Type           : [Not Occupied]
Size           :

有多个错误代码组成此症状代码。其中大多数不需要任何作。以下事件代码需要作。

请注意,错误代码可能被指定为 Event Code、MessageID 或 Code:

 
错误代码 描述 建议的作
MEM0001 在内存设备的位置 arg1 处检测到多位内存错误。 立即更换 DIMM。
MEM0702 系统检测到并纠正了内存错误 重新启动系统以启用潜在的内存自我修复。
MEM9072 系统内存在位于位置 arg1 的内存设备的非执行路径中存在不可纠正的多位内存错误。 立即更换 DIMM
MEM0702 
“Correctable memory error rate exceeded for DIMM_XX.”
立即更换 DIMM

如果上述建议的作是更换 DIMM,请使用连接器名称指定应更换的插槽。无需像 Gen4t 中那样更换多个插槽。

Produse afectate

Avamar Data Store Gen5A
Proprietăți articol
Article Number: 000214852
Article Type: Solution
Ultima modificare: 03 Aug 2026
Version:  9
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.