PowerScale: SyncIQ ei replikoi käyttöaikaa (atime) kohdeklusteriin
Summary: Kun tietoja replikoidaan SyncIQ:n avulla, jos tiedostojen käyttöaika (atime) on muuttunut tuotantoklusterissa. Käyttöaikaa (atime) ei replikoida kohdeklusteriin, kun SyncIQ suorittaa replikoinnin loppuun. ...
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
Example:
Source:
SIQ1-1# stat -x /ifs/data/Sync_Test1
File: "/ifs/data/Sync_Test1"
Size: 8347045 FileType: Regular File
Mode: (0777/-rwxrwxrwx) Uid: (1001450/(1001450)) Gid: (1000069/(1000069))
Device: 136,1757282482 Inode: 4314169351 Links: 3
Access: Wed Jun 14 13:56:49 2023 <-- Access Time is newer than Target Access Time
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 09:08:41 2023
Target:
SIQ-2# stat -x /ifs/data/Sync_Test1
File: "/ifs/data/Sync_Test1"
Size: 8347045 FileType: Regular File
Mode: (0777/-rwxrwxrwx) Uid: (1000759/(1000759)) Gid: (1000195/(1000195))
Device: 18446744073709551597,18446744072263041268 Inode: 51447964289 Links: 3
Access: Sun Jun 11 09:08:35 2023 <-- Target Access time is not updated
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 10:21:48 2023Cause
SyncIQ perustaa kaiken muutosten siirron tilannevedoksessa näkyviin attribuutteihin. SyncIQ voi siirtyä vain kerran lähteestä kohteeseen. Kun lähdetiedostoon on tehty jokin muu muutos, joka laukaisee COW:n, esimerkiksi käyttöoikeuksien muutos.
Resolution
Tämä on tarkoituksellista. Tulevaa koodia varten on lähetetty ominaisuuksien parannuspyyntö.