Customer Notice: Installation of the 2025 R1 OS Security Rollup May Fail on Avamar Data Store Gen4T and Gen4S Multi-Node Systems

Summary: Installation of the 2025 R1 OS Security Rollup may fail on Dell Avamar Data Store Gen4T and Gen4S multinode systems.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

An issue has been identified in Dell Avamar Data Store environments running Gen4T and Gen4S hardware. The 2025 R1 OS Security Rollup may fail during reboot on nonutility nodes, leaving storage nodes offline and disrupting the installation process. 

Note: This issue does not affect systems running Gen5A hardware.

Cause

A failure to install the GRand Unified Bootloader (GRUB2) on Gen4T and Gen4S storage nodes causes this issue. When this occurs, the operating system is unable to boot correctly, leaving the affected nodes offline. Customers are advised not to install the 2025 R1 OS Security Rollup on any multinode Avamar Data Store Gen4T or Gen4S systems. 

Resolution

Customers can resolve this issue by installing the 2025 R2 OS Security Rollup. For additional details, refer to KB 000351152 titled DSA-2025-293: Security update for Dell Avamar, Dell Networker Virtual Edition (NVE) and Dell PowerProtect DP Series Appliance / Dell Integrated Data Protection Appliance (IDPA) Multiple Third-Party Vulnerabilities.

Affected customers should initiate a support case with Dell Technical Support when failure symptoms are detected. Provide Avamar system ID and details of any affected nodes to help expedite resolution.

Produse afectate

Avamar Data Store Gen4T, Avamar Server
Proprietăți articol
Article Number: 000334245
Article Type: Solution
Ultima modificare: 21 Jan 2026
Version:  5
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.