Isilon OneFS: "lwmsg_call_dispatch" Error Occurs When Running "isi services" Command on the Cluster

Summary: Running the "isi services -a/-l" command returns an error: "lwmsg_call_dispatch failed: 16"

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

When users run command "isi services -a/-l" to list the services running on the cluster, they get below error:

Cluster-2# isi services -a
Available Services:
lwmsg_call_dispatch failed: 16

 

Cause

This is because of mcp process is not running on the cluster.

 

Resolution

  1. Check whether the mcp process is running on the cluster or not

    Cluster-2# isi_for_array -s ps -auxww | grep -i mcp | grep -v grep
    Cluster-2#
  2. Start the mcp process on the cluster

    Cluster-2# isi_for_array -s isi_mcp
    Cluster-2#
  3. Verify the mcp process

    Cluster-2# isi_for_array -s ps -auxww | grep -i mcp | grep -v grep
    Cluster-1: root   76482   2.0  0.6 152080 11884  -  Is   10:38PM    0:01.44 isi_mcp: master (isi_mcp)
    Cluster-1: root   76478   0.0  0.5 150156 10248  -  Is   10:38PM    0:00.03 isi_mcp: failsafe (isi_mcp)
    Cluster-1: root   76480   0.0  0.5 149900 10260  -  Ss   10:38PM    0:00.00 isi_mcp: forker (isi_mcp)
    Cluster-2: root   55647   1.0  0.6 152080 12512  -  Is   10:38PM    0:01.00 isi_mcp: master (isi_mcp)
    Cluster-2: root   55643   0.0  0.5 150156 10888  -  Is   10:38PM    0:00.03 isi_mcp: failsafe (isi_mcp)
    Cluster-2: root   55645   0.0  0.5 149644 10848  -  Is   10:38PM    0:00.00 isi_mcp: forker (isi_mcp)
    Cluster-2#

 

Produse afectate

PowerScale OneFS

Produse

PowerScale OneFS
Proprietăți articol
Article Number: 000050177
Article Type: Solution
Ultima modificare: 03 mar. 2026
Version:  4
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.