MFE TF Clone/Snap: EMCSNAP cannot create a new session. Reason code 170061
Summary: The EMCSNAP operation fails to create a new session due to a session limit being exceeded.
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
SNAP DATASET or SNAP VOLUME operation fails.
EQCA027E SCSI(812B) BAD RC, 3E DATA 170061
ESNP537E EMC SNAP API - I/O ERROR CREATING SNAP SESSION
Reason code: 170061 (The request to establish an extent failed. The maximum of sessions has been exceeded)
EMCSNAP fails to create a new session with reason code 170061.
Cause
Either the limit of 16 sessions per device, or of 64 sessions per Subsystem Identifier (SSID), has been reached.
Resolution
Use one of the following options to reduce or remove SNAP sessions before rerunning the failed SNAP job:
- Wait for previous SNAP sessions to complete
- Use the
STOP SNAPcommand. - Use the
CLEANUP EXTENT TRACKcommand to remove old SNAP sessions.
For more details about the above commands refer to Mainframe Enablers TimeFinder/Clone Mainframe Snap Facility Product Guide.