Data Domain: SRM Discovery Issues with Timed Out Errors

Summary: The article describes timeout failures during SRM discovery of Data Domain systems. Long polling cycles and TTL expirations are caused by the maxBulkSize value being too large.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

Discovery issues occur on Data Domain systems. Timeout errors are reported. These same Data Domain systems were discovered earlier without issues. Increasing the timeout to 1200 only cleared the issue for some Dell Data Domain appliances.

The Data Domain collector log shows the following generic errors:

WARNING -- [2023-02-15 10:59:00 MST] -- PollingUnitPollingGroup::waitAtEndOfPollingCycle(): Polling group 300.EMC-DATA-DOMAIN-BOOST.EMC-DATA-DOMAIN-CIFS.EMC-DATA-DOMAIN-DISK.EMC-DATA-DOMAIN-ENV.EMC-DATA-DOMAIN-FS.GENERIC-INTERFACES.GENERIC-HOST-RESOURCES-PROCESSOR.GENERIC-HOST-RESOURCES-STORAGE.EMC-DATA-DOMAIN-MTREE.EMC-DATA-DOMAIN-NFS.EMC-DATA-DOMAIN-QUOTA.EMC-DATA-DOMAIN-REPLICATION.GENERIC-SYSUPTIME.EMC-DATA-DOMAIN-SYSTEM.EMC-DATA-DOMAIN-VTL is taking too long: Completed in 425081ms. Skipping next polling cycle. 174919ms until next polling, at timestamp: 1676484115000

WARNING -- [2023-02-15 11:01:56 MST] -- PollingUnitTable::closeSession(): Interrupted session on xxx-xxxxxx.xx.xx.org:161 : Time to live has expired.

 

Cause

The default maxBulkSize of 50 was causing discovery timedout errors.

 

Resolution

In the incident that generated this KB article, reducing the maxBulkSize value cleared the discovery issue.
Set the maxBulkSize value to a lower number, such as 15.