PowerProtect Cyber Recovery: Error - "The storage interface name provided for multilink object is not valid"

Summary: Error when adding an interface to Multilink, stating that the object is invalid.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

Customer is getting this error when trying to configure multi link. 
 
ERROR: Failed to modify application:<CyberSense Server hostname> 
The storage interface name vethx.xxx provided for multilink object with storage ID xxxxx is not valid.



Cause

Issue is due to a limitation with the number of interfaces on the vault Data Domain being more than 20.

Resolution

DD ../network/interfaces REST API only returns 20 interfaces by default, this has been extended to 100 in CR Release 19.13.0.3.

Release Notes/Installation guide for multilink configuration prerequisites must be followed to avoid further issues. 