Connectrix: Brocade: Chassis switch is not responding to Data request

Summary: Error is seen on the chassis when the Switch is not responding or accessible intermittently.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

Chassis shows the below error:
The IO Module in Slot C1 is not responding to data requests due to communication error. 


IO Module in Slot C1

Cause

Caused while due to lose connectivity between chassis pins and Switch module due to physical activity on the chassis.

Resolution

Scheduled a maintenance window and re-seat the affected Switch in the chassis. 

NOTE: Verify that multipathing of servers is working fine so that the path can be failed over to redundant switch in the same chassis. 