Cisco MDS:%PORT-4-TRANSCEIVER_DUPLICATE_WARNING

Summary: Customer received duplicate transceiver warning after swapping SFP.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

2024 Sep  8 16:30:30 switch01 %PORT-4-TRANSCEIVER_DUPLICATE_WARNING: Transceivers for Interfaces (fc4/25 fc4/27) contain duplicate Serial numbers (FNSxxxxxxxx)

2024 Sep 15 16:30:21 switch01 %PORT-4-TRANSCEIVER_DUPLICATE_WARNING: Transceivers for Interfaces (fc4/25 fc4/27) contain duplicate Serial numbers (FNSxxxxxxxx)

Cause

To prevent this problem from happening, insert or remove one SFP at a time waiting at least two s before inserting or removing another SFP.

Resolution

If this problem has already happened, Non-disruptively reload the linecard to recover.

reload module x non-disruptive

 

Produse afectate

Connectrix, Connectrix MDS-Series Hardware

Produse

VxBlock and Vblock Systems, Connectrix MDS-9710-V2, Connectrix MDS-Series Firmware, Connectrix MDS-Series Firmware 9.X
Proprietăți articol
Article Number: 000239404
Article Type: Solution
Ultima modificare: 19 mai 2025
Version:  1
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.