PowerFlex: SO Node deployment fails as the OS repository is missing DellEMCPowerFlexEMbeddedOS2
Summary: Storage Only (SO) Node Deployment fails as the OS repository is missing on the MVMs after a resynchronization.
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
SO node deployment fails after a resynchronization of the repository. New OS directories are created, and the expected OS directory is not available on the MVMs.
Cause
-
DellEMC PowerFlex EMbeddedOS 3 (RHEL) and DellEMC PowerFlex EMbeddedOS 4 (SUSE) were created after a resync.

- PowerFlex Manager was trying to deploy using DellEMC PowerFlex EMbeddedOS 2 (SUSE)
-
In
/opt/platfrom/fileshare/[deploymentID]/on each MVM the DellEMCPowerFlexEMbeddedOS2 is no longer available.
Resolution
Create the directory and copy the contents from the required repository and retry the deployment. As this was a SUSE deployment, The neeeded files are from DellEMCPowerFlexEMbeddedOS4.
Example:
cp -r DellEMCPowerFlexEMbeddedOS4 DellEMCPowerFlexEMbeddedOS2