PowerVault ME5: Disk Group Creation errors when using Select All checkbox

Summary: Creating a linear RAID array using the ME5 user interface, selecting all available disks may result in the Sub Groups not being populated correctly. This issue occurs across all RAID levels. ...

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

During linear disk group creation, using the select all check box option at the top of Available Disks, does not create the disk group when the Add Disk Group button is selected.

Figure 1:

Add disk group

Cause

Firmware code version 5.1.2.1.1 and earlier

Resolution

Dell Engineering is working on a resolution.

A workaround is available:

  1. Select all available disks
  2. Click one disk to clear its selection
  3. Re-select the disk clicked in step 2
  4. Proceed with creating the disk group

This issue relates to all disk group types.

A firmware update to address this issue is planned for release in the September to October 2025 timeframe.

Until the fix is available, users can use the workaround described above to successfully create disk groups.