OneFS: The /var/crash Partition of a Node in the Cluster has Reached 90 Percent Capacity

Zhrnutie: The /var/crash partition of a node in the cluster has reached 90% capacity alert-Event ID: 100010002

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Symptómy

Running with a full /var/crash partition is unlikely to lead to problems, but may prevent some debugging information from being saved if other issue arises. This alert could indicate that processes may be dumping core and this behavior should be investigated.

Introduction

You might receive an alert warning that the crash partition of a node in the cluster, /var/crash, has reached 90% capacity. The /var/crash partition is used to store core files from running services that have become unresponsive. This alert could indicate that processes may be dumping core and this behavior should be investigated.

Príčina

The /var/crash partition stores core files from running services that have become unresponsive. It might also contain log gather data or temporary files created and stored by technical support or the user.

Riešenie

Details

To see what is taking up space in the /var/crash partition, run the following command on any node in the cluster:

isi_for_array -s 'df -h'
isi_for_array -s 'find /var/crash -type f -size +10000 -exec ls -lh {} \;'

If you want assistance from Dell Support to investigate the issue alert, include the results of the above command in your initial email. It would also be helpful if the logs from the cluster can be reviewed.

If a core file is filling the /var/crash partition, the file should be saved temporarily to somewhere in /ifs/data/Isilon_Support and the offending service should be investigated for the cause.

A patch may exist for the specific OneFS version, it may be fixed in a later version, or a new tracking issue may be opened for the issue.

Ďalšie informácie

Related article:

  • Event notification: Node reached 95% used capacity on the root file system, 000016965.

Dotknuté produkty

Isilon Gen6.5, Isilon Gen6, PowerScale OneFS