Zhrnutie: This article describes how to perform the disk rescan procedure on a Dell Data Domain system. The rescan operation manually polls all disk drives, forcing the system to reevaluate their state. While DDOS typically performs automatic scans, a manual rescan may be necessary if a replacement disk is not recognized. ...

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Symptómy

Warning: This procedure applies only to single disk absent alerts. Do not use this method if multiple disks are reporting absent, as this may risk data loss.
 
Applies to:
  • All Data Domain systems
  • All software Versions

Symptoms

  • Autosupport alerts such as:
Err Code: STORAGE-00002 | STORAGE00002
Enclosure disk is absent and should be replaced
Disk in Absent State
  • Disk not recognized after replacement
  • Unable to bring the disk into a usable state (in-use or spare)

Príčina

Sometimes, DDOS may fail to detect a newly inserted disk due to:

  • Background processes interfering with disk discovery
  • Disk replaced too quickly before the system completed its internal checks
  • Transient hardware or communication issues

Riešenie

Follow these steps to perform a disk rescan:

  1. Initial Rescan
    At the CLI prompt, run:

    • disk rescan
    • Wait for the command prompt to return.

    • If the disk is still reported as 'Absent', follow the steps below.
  2. Remove the Disk Drive
    Carefully remove the disk in question.

  3. Inspect the Disk

    • Check terminal connectors for debris or bent/damaged pins.
    • If pins are damaged, replace the disk.
  4. Wait for Detection Timeout

    • Allow 2 minutes for the SAS backplane to register the removal.
  5. Trigger Second Rescan
    At the CLI prompt, run:

    • disk rescan
    • Wait for the command prompt to return.

  6. Reinsert the Disk

    • Firmly reinsert the disk into its original slot.
    • Wait another 2 minutes for DDOS to detect the change.
  7. Verify Disk State

    • Run disk show hardware or disk show state to confirm the disk is now listed as in-use or spare.

Dotknuté produkty

Data Domain

Produkty

Data Domain
Vlastnosti článku
Číslo článku: 000045237
Typ článku: Solution
Dátum poslednej úpravy: 07 okt 2025
Verzia:  3
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.