Connectrix MDS: The preupgrade check failed. Return code 0x402000EF

Zhrnutie: The preupgrade check failed. Return code 0x402000EF Zone change in progress, ISSU rejected. Either commit or no commit (discard) the changes from the switch.

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Symptómy

Customer performing NX-OS preupgrade checks 

Customer NX-OS upgrade prechecks are failing as follows:-
Performing Compact Flash and TCAM sanity test.
[####################] 100% -- SUCCESS

Performing module support checks. [####################] 100% -- SUCCESS

Notifying services about system upgrade. [# ] 0% -- FAIL.
Return code 0x402000EF (Zone change in progress, ISSU rejected.).

Pre-upgrade check failed. Return code 0x402000EF (Zone change in progress, ISSU rejected.).

Show zone status:
VSAN: 1000 default-zone: deny distribute: full Interop: default
    mode: enhanced merge-control: allow
    session: remote [dom: 1][ip: 1xx.1xx.1xx.1x] <===========

Session held by the above switch

Príčina

Zoning lock

Riešenie

Fix:
-Either commit or no commit (discard) the changes from the switch. 
      Config
      Zone commit vsan 1000
 Or
      Config
     no zone commit vsan 1000

 -admin can log in to switch and discard the changes by clearing the zone lock:

 Clear zone lock vsan 1000

Dotknuté produkty

Connectrix MDS-Series Firmware 6.X

Produkty

Connectrix MDS-Series Firmware 6.X, Connectrix MDS-Series Hardware
Vlastnosti článku
Číslo článku: 000055150
Typ článku: Solution
Dátum poslednej úpravy: 30 sep 2025
Verzia:  3
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.