NetWorker: v9.0 VMware-töitä ei voi kloonata CloudBoost-laitteeseen
Zhrnutie: VMware vProxyn tallennusjoukkojen kloonaus CloudBoostiin epäonnistuu. Virheelliset tallennusjoukon tunnukset, ei työkohteita, virhe: pooli tuetuilla solmuilla; Syy: solmuversio 9.1.
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
VMware-varmuuskopioiden (vProxy-varmuuskopiointi) tallennusjoukkojen kloonaus CloudBoost-laitteeseen epäonnistuu.
mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid <SSID> mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. . mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list. mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS! mm/dd/yyyy hh:mm:ss meridiem No valid backend job mm/dd/yyyy hh:mm:ss meridiem [ORIGINAL REQUESTED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/; mm/dd/yyyy hh:mm:ss meridiem [CLONE SKIPPED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>; mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1 mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.
Virheen daemon-lokin < tarkastelu virheen hetkellä kk/pp/vv hh:mm:ss meridiem> löytää viestin:
71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>' 165718 mm/dd/yyyy hh:mm:ss meridiem 5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>. 71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '. 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed 89017 mm/dd/yyyy hh:mm:ss meridiem 1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
Príčina
Pyydä parannusta. Tunnettu ongelma: NW-I-404: NetWorker: Kloonaus vProxy-tallennusjoukoilla CloudBoost-laitteeseen.
Riešenie
Tuotehallinta tutkii parannuspyyntöä. Pyyntöä käsitellään edelleen. Ota yhteyttä asiakastukikeskukseen saadaksesi apua ja mainitse tämän artikkelin numero.
TILAPÄISRATKAISU: Kun käytössä on NetWorker 9.0.1 tai uudempi tietovyöhyke, määritä ulkoinen tallennussolmu. Katso NetWorker 9.1 CloudBoost 2.1 Integration Guide -oppaan osasta NetWorker 9.1: Laitteen määrittäminen käyttämällä ulkoista tallennussolmua CloudBoostia varten".
TILAPÄISRATKAISU: Kun käytössä on NetWorker 9.0.1 tai uudempi tietovyöhyke, määritä ulkoinen tallennussolmu. Katso NetWorker 9.1 CloudBoost 2.1 Integration Guide -oppaan osasta NetWorker 9.1: Laitteen määrittäminen käyttämällä ulkoista tallennussolmua CloudBoostia varten".