NetWorker: v9.0 VMware 작업을 CloudBoost 디바이스에 복제할 수 없음

Zhrnutie: VMware vProxy 세이브 세트를 CloudBoost로 복제할 수 없습니다. 잘못된 세이브 세트 ID, 작업 항목 없음, 오류: 지원되지 않는 노드가 있는 풀입니다. 원인: 노드 버전 9.1.

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Symptómy

 

VMware 백업(vProxy 백업) 세이브 세트를 CloudBoost 디바이스로 복제하는 작업이 실패합니다.

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

실패의 mm/dd/yyyy hh:mm:ss meridiem> 시간에 < 데몬 로그를 검토하면 다음과 같은 메시지가 발견됩니다.

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Príčina

개선 요청. 알려진 문제: NW-I-404: NetWorker: CloudBoost 어플라이언스에 vProxy 세이브 세트의 클론을 생성하는 중입니다.

Riešenie

제품 관리에서 이 개선 요청을 조사하고 있습니다. 요청이 아직 진행 중입니다. 고객 지원 센터에 문의하여 지원을 요청하고 문서 번호를 알려주십시오.

해결 방법: NetWorker 9.0.1 이상의 데이터 존에서 외장형 스토리지 노드를 구성합니다. 자세한 내용은 "NetWorker 9.1 CloudBoost 2.1 통합 가이드"의 "NetWorker 9.1: CloudBoost용 외장형 스토리지 노드를 사용하여 디바이스 구성"

Dotknuté produkty

Cloud Backup & Protection, NetWorker
Vlastnosti článku
Číslo článku: 000065416
Typ článku: Solution
Dátum poslednej úpravy: 04 dec 2025
Verzia:  5
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.