NetWorker: v9.0 Não é possível clonar trabalhos VMware para o dispositivo CloudBoost

Zhrnutie: Falha na clonagem de savesets do VMware vProxy para o CloudBoost. IDs de saveset inválidos, nenhum item de trabalho, erro: pool com nós incompatíveis; Causa: versão 9.1 do nó.

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Symptómy

 

A clonagem de savesets de backups VMware (backup do vProxy) para um dispositivo CloudBoost apresenta falha.

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

A análise do log do daemon no momento <mm/dd/aaaa hh:mm:ss meridiem> da falha encontra a mensagem:

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Príčina

Solicitação de aprimoramento. Problema conhecido: NW-I-404: NetWorker: Clonando savesets do vProxy para um equipamento CloudBoost.

Riešenie

O gerenciamento de produtos está investigando esta solicitação de aprimoramento. A solicitação ainda está em andamento. Entre em contato com o Centro de suporte ao cliente para obter assistência e mencione o número deste artigo.

SOLUÇÃO ALTERNATIVA: Com uma zona de dados do NetWorker 9.0.1 ou posterior, configure um nó de armazenamento externo, consulte o "Guia de integração do NetWorker 9.1 CloudBoost 2.1" na seção "NetWorker 9.1: Configurando um dispositivo usando um nó de armazenamento externo para CloudBoost".

Dotknuté produkty

Cloud Backup & Protection, NetWorker
Vlastnosti článku
Číslo článku: 000065416
Typ článku: Solution
Dátum poslednej úpravy: 04 dec 2025
Verzia:  5
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.