Symptómy

If the Intel IPU is rebooted through the IMC while using the Management Interface Card (MIC), the entire server reboots.

This only occurs when accessing the IPU through the iDRAC console "connect dpu1."

Event log status
 

Príčina

The IPU attempts to reboot, but when the reset fails, the driver clears the reset state as part of its error handling. This creates an issue because the driver relies on the reset state to schedule the statistics task.

Riešenie

This issue is addressed in IPU software release 1.7.0. Update to the latest version to resolve it.