Dell Networking Enable HTTPS and SSH and Disable HTTP and Telnet for Switch Management on Legacy PowerConnect 7000 and N-series Switches
摘要: How to restrict management access to HTTPS and SSH on PowerConnect 7000.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
说明
This article provides the steps necessary to restrict management access to HTTPS and SSH on PowerConnect 7000.
This procedure assumes:
This procedure assumes:
- The switch is already configured with an IP address and is reachable within the network.
- There is an account created with Privilege Level 15. To verify this, use the command:
show users accountsFor newer N-Series switches and additional management options, see How to set up management access for Dell Networking N2000, N3000, and N4000 Series Switches.
- Connect to the switch by the console, telnet, or ssh.
- The 7000 series requires a Privileged Exec (Enable) mode password for remote management over ssh or telnet. Failure to set this password may result in severely limited CLI management ability. Add an enable password:
console> enable console# config console(config)# enable password MYPASSWORD
- To enable SSH, enter the following commands:
console(config)# crypto key generate rsa console(config)# crypto key generate dsa console(config)# ip ssh server
If issues arise with specific commands, ensure you are running the latest firmware version.
Caution: Before disabling either telnet or HTTP access, verify SSH or HTTPS access.
- To disable telnet, run:
console(config)# ip telnet server disable
- To enable HTTPS, enter the following commands:
console(config)# crypto certificate 1 generate console(config-crypto-cert)# key-generate <512-2048> console(config-crypto-cert)# exit console(config)# ip http secure-certificate <1 - 2> Instance of the certificate to be activated. console(config)# ip http secure-server
This system can generate and store two certificates. To generate the second key, replace the number 1 with 2. To activate the second key, use:
(config)# ip http secure-certificate 2
- To disable HTTP, enter:
console(config)# no ip http server
- After verifying connectivity using SSH or HTTPS, save the configuration by entering:
console# copy running-config startup-config
Note: After completing these steps, expect to receive errors about certificate authenticity. These are due to the certificates and keys being self-generated. This is not an error.