Data Domain:檔系統 (DDFS) 會在系統記錄中充水,並出現網路篩選訊息時重新啟動
摘要: 如果系統記錄充滿並附有 Net Filter 訊息,Data Domain 檔案系統 (DDFS) 可能會重新啟動 (請參閱範例)
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
如果系統記錄充滿並附有 Net 篩選器訊息,Data Domain 檔案系統 (DDFS) 可能會重新啟動。
例子:
尋找關鍵字 net_filter:
sms.info 檔案中也回報類似的訊息:
大量網路篩選器訊息觸發 DDFS 以重新啟動,並出現下列其中一種徵狀:
例子:
#log 檢視偵錯/messages.engineering <– 這會在 VI 編輯器中開啟檔案
尋找關鍵字 net_filter:
Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for ::/0:161 program_name snmpd Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:161 program_name snmpd Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for ::/0:161 program_name snmpd Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:161 program_name snmpd Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for ::/0:919 program_name rpcbind Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:919 program_name rpcbind Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for ::/0:919 program_name rpcbind Feb 24 16:15:54 dd01 sms: ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:919 program_name rpcbind
#log view debug/sm/sms.info 02/24 16:11:49.043 (tid 0xf2ad5b0): ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:111 program_name rpcbind 02/24 16:11:49.053 (tid 0xf2ad5b0): ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:111 program_name rpcbind 02/24 16:11:49.063 (tid 0xf2ad5b0): ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:161 program_name snmpd 02/24 16:11:49.072 (tid 0xf2ad5b0): ERROR: sms_net_filter_check_add_auto_services: service could not be updated for 0.0.0.0/0:161 program_name snmpd 02/24 16:11:49.081 (tid 0xf2ad5b0): ERROR: sms_net_filter_check_add_auto_services: service could not be updated for ::ffff:127.0.0.1:8009 program_name java 02/24 16:11:49.090 (tid 0xf2ad5b0): ERROR: sms_net_filter_check_add_auto_services: service could not be updated for ::ffff:127.0.0.1:8009 program_name java 02/24 16:11:49.099 (tid 0xf2ad5b0): ERROR: sms_net_filter_check_add_auto_services: service could not be updated for ::/0:809 program_name dd_vrr_vtl
- NFS RPC 逾時
- HMON 逾時
- CROND 逾時
- 目錄管理員代碼
PANIC:ddr/fm/fm_fastcopy.c:fms_is_new_content:326: 嚴重錯誤
原因
在 DDOS 6.x 中,系統會導入 Net Filter 功能,以使用自動設定清單來設定防火牆設定。工程部門發現網路篩選器功能出現程式碼瑕疵,導致大量訊息記錄在 messages.engineering 和 sms.info 中。
解决方案
Dell 工程部門已解決此問題。參考缺陷 DDOSCFD-2546。DDOS 6.2.1.30 或更新版本包含缺陷修正程式。
在 DDOS 升級之前,可以套用下列因應措施。
在 DDOS 升級之前,可以套用下列因應措施。
# net filter show map all # net filter auto-list delete ports all # net filter stop # net filter enable # net filter enable all
受影响的产品
Data Domain产品
DD OS 6.2, DD OS 6.0, DD OS 6.1文章属性
文章编号: 000184251
文章类型: Solution
上次修改时间: 04 9月 2025
版本: 3
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。