Dell Unity: Frequently Asked Questions (FAQ) about how disk firmware is upgraded (User Correctable)
摘要: This article answers some frequently asked questions about how the disk firmware is upgraded.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
说明
- When a disk firmware upgrade in the GUI is triggered, every disk will request upgrade permission from Raid.
- If the Raid Group (RG) is not in a degraded status, the upgrade will be performed. Otherwise, the upgrade request will be denied.
- The upgrade process operates on multiple drives (but only one drive max per RAID group). The upgrade process also upgrades unused drives in parallel.
- The disk firmware upgrade within the same RG is executed one by one; But different RGs can perform the upgrade in parallel.
- The order of disks being upgraded within the same RG follows the order of their Physical Disk Object's (PDO).
- Hot spare drives can run the firmware upgrade in parallel.
- One type of disk would be upgraded first before it moves on to another type of disk.
- The limitation of concurrent disk upgrade operations is not found in the code.
受影响的产品
Dell EMC Unity文章属性
文章编号: 000184676
文章类型: How To
上次修改时间: 12 12月 2025
版本: 3
从其他戴尔用户那里查找问题的答案