Isilon PowerScale CloudIQ: Isilon Cluster is enabled under CloudIQ but not connected

摘要: Isilon cluster stopped collecting CloudIQ data.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

CloudIQ Portal shows the Isilon cluster Secure Remote Services (SRS) enabled and CloudIQ enabled.

CloudIQ Portal shows connectivity stopped.

All the prerequisites are met as per onboarding KB 157794: Isilon-PowerScale CloudIQ: General procedures to onboard Isilon to CloudIQ  

Secure Remote Services is showing the Cluster managed under a gateway with a status of good.

Running the httpd logs on the gateway shows connection to the keepalive within the access logs but no mft data is being sent:    

10.xx.xx.xx - - [12/Apr/2021:16:04:07 +0000] "POST /esrs/v2/devices/ISILON-GW/EXXISLxxxxx/keepalive HTTP/1.1" 200 171 0
10.xx.xx.xx - - [12/Apr/2021:16:05:07 +0000] "POST /esrs/v2/devices/ISILON-GW/EXXISLxxxxx/keepalive HTTP/1.1" 200 171 0
10.xx.xx.xx - - [12/Apr/2021:16:06:08 +0000] "POST /esrs/v2/devices/ISILON-GW/EXXISLxxxxx/keepalive HTTP/1.1" 200 171 0

PrintEmail
English

原因

Telemetry is disabled on the cluster side.

解决方案

To confirm, from the command line, run the isi esrs telemetry view command:      
Telemetry Enabled: No
  Pending uploads: 0

If telemetry is not enabled, run the isi esrs telemetry modify --enabled=true to enable it.
文章属性
文章编号: 000185206
文章类型: Solution
上次修改时间: 09 5月 2026
版本:  5
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。