MHC Azure Stack: Tipo OEM FirmwareCheckHealth de la función OEM emitió una excepción

摘要: Type FirmwareCheckHealth of Role OEM raised an exception Error running Test-OEMFirmwareHealth iDRAC has Critical Major faults could not proceed with Firmware update.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

La verificación previa de OEM falla Errores:
Oem Package Update
Perform Oem Extension update.

BeforeOEMUpdate
Tasks before OEMUpdate.

Test Firmware PreUpdate
Determine if OEM Firmware should be updated on physical nodes.

Firmware Check Health.
Check firmware health before update.

OEM.png

Haga clic en "Download Summary".

Error.json: 
Type ‘FirmwareCheckHealth’ of Role ‘OEM’ raised an exception:\n\nError running Test-OEMFirmwareHealth: iDRAC: 10.224.190.3 has Critical Major faults, could not proceed with Firmware update….

OEMerror.png
 

原因

Tres de los cuatro servidores tenían errores de memoria. Estos se deben resolver antes de continuar. 
The memory health monitor feature has detected a degradation in the DIMM installed in DIMM_A6. Reboot system to initiate self-heal process.

解决方案

Para resolver este problema, corrija los errores de memoria.

  1. Drene el nodo con la iDRAC en el que se muestra la memoria fallida. 
  2. Una vez drenado, ejecute los siguientes comandos en una ventana de PowerShell PEP. 
get-virtualdisk -cimsession "s-cluster"
get-virtualdisk -cimsession "s-cluster" | get-storagejob
  1. Una vez que se completen todos los trabajos de almacenamiento, realice un arranque en frío del servidor desde iDRAC
  2. Verifique que el DIMM se haya reparado:
    The self-heal operation successfully completed at DIMM DIMM_A6.
  3. En la ventana Azure Stack, inicie el nodo.
  4. En la ventana Azure Stack, reanude el nodo.

受影响的产品