MHC Azure Stack: OEM Type FirmwareCheckHealth of Role OEM ha generato un eccezione
摘要: Type FirmwareCheckHealth of Role OEM raised an exception Error running Test-OEMFirmwareHealth iDRAC has Critical Major faults could not proceed with Firmware update.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
Il controllo preliminare dell'OEM non riesce Errori:
Cliccare su "Download Summary".
Error.json:
Oem Package Update Perform Oem Extension update. BeforeOEMUpdate Tasks before OEMUpdate. Test Firmware PreUpdate Determine if OEM Firmware should be updated on physical nodes. Firmware Check Health. Check firmware health before update.
Cliccare su "Download Summary".
Error.json:
Type ‘FirmwareCheckHealth’ of Role ‘OEM’ raised an exception:\n\nError running Test-OEMFirmwareHealth: iDRAC: 10.224.190.3 has Critical Major faults, could not proceed with Firmware update….
原因
Tre dei quattro server presentavano errori di memoria. Questi problemi devono essere risolti prima di procedere.
The memory health monitor feature has detected a degradation in the DIMM installed in DIMM_A6. Reboot system to initiate self-heal process.
解决方案
Per risolvere questo problema, correggere gli errori di memoria.
- Scaricare il nodo con l'istanza di iDRAC contenente la memoria guasta.
- Al termine, eseguire i seguenti comandi in una finestra PowerShell PEP.
get-virtualdisk -cimsession "s-cluster" get-virtualdisk -cimsession "s-cluster" | get-storagejob
- Una volta completati tutti i processi di storage, avviare a freddo il server da iDRAC
- Verificare che il modulo DIMM sia stato riparato:
The self-heal operation successfully completed at DIMM DIMM_A6.
- Nella finestra di Azure Stack avviare il nodo.
- Nella finestra di Azure Stack riattivare il nodo.