PowerStore: Adding Initiator fails with error "Cannot add IQN since it already exists as part of the host (0xE0A01001000C)"
摘要: Adding Initiator fails with error "Cannot add IQN since it already exists as part of the host (0xE0A01001000C)"
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
Appliance running PowerStore OE 2.2.1
Two hosts (host1 and host2) were mistakenly assigned initiators with the same WWPN
The duplicate WWPN is deleted from host1
The GUI and PSTCLI output do not show the deleted WWPN in use by any host.
Trying to add the WWPN that was deleted from host1 to host2 fails with error "Cannot add IQN since it already exists as part of the host (0xE0A01001000C)"
Note: Ignore the IQN reference, the issue is applicable to any initiator type.
Example of Issue:
The initiator we are trying to add will also not be found in any other host using PSTCLI
Two hosts (host1 and host2) were mistakenly assigned initiators with the same WWPN
The duplicate WWPN is deleted from host1
The GUI and PSTCLI output do not show the deleted WWPN in use by any host.
Trying to add the WWPN that was deleted from host1 to host2 fails with error "Cannot add IQN since it already exists as part of the host (0xE0A01001000C)"
Note: Ignore the IQN reference, the issue is applicable to any initiator type.
Example of Issue:
- Create 2 hosts, host1 with WWPN A, B, host2 with WWPN C.
- Add those hosts into a host group.
- Add WWPN A to host2. It was successful. Now each host has 2 initiators. This is wrong. 2 hosts cannot use the same WWPN.
- Remove WWPN A from host1. WWPN A appears to be removed from both hosts on GUI, but it's not removed from underlying database for host2.
- Now try to add WWPN A to host2. It fails with the error "Cannot add IQN since it already exists as part of the host (0xE0A01001000C)"
The initiator we are trying to add will not be listed under the host in the GUI.
The initiator we are trying to add will also not be found in any other host using PSTCLI
"host show -select name, os_type, host_initiators"
原因
There is an issue with PowerStore OE 2.1.1.1 that allows adding a duplicate initiator to an existing host.
解决方案
Workaround:
If this issue is encountered please contact Dell Technical Support and reference this article for assistance.
Fix:
This issue is corrected in PowerStore OE 3.0.0.1 and above.
If this issue is encountered please contact Dell Technical Support and reference this article for assistance.
Fix:
This issue is corrected in PowerStore OE 3.0.0.1 and above.
受影响的产品
PowerStore文章属性
文章编号: 000205128
文章类型: Solution
上次修改时间: 27 7月 2023
版本: 3
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。