PowerStore: Node fails to join back to the cluster

摘要: PowerStore node fails to join back to the cluster following an unexpected reboot due to a hardware issue, software issue, or a node replacement.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

Possible alerts:

  • The frontend ports report link state down and small form-factor pluggable (SFP) health disconnected state.
  • 0x0030A105 - Alert generated for SFP module not inserted or seated correctly.
  • 0x00304404 - Node was physically removed or shut down.
  • 0x0030CB01 - I/O is not ready on the node.
  • 0x00307701 - XENV is not active.
  • The node life cycle state changed (disconnected).
  • The node's I/O service level changed (not_ready). DataPath (DP) fails to start on the node.
  • No hardware faults on the nodes.

原因

This is due to a rare condition that can occur on systems running PowerStoreOS 3.x versions. An internal system process fails to trigger a node failover after an unexpected node reboot. Once the node comes back up, it fails to join back to the cluster.

解决方案

This issue is addressed in PowerStoreOS 3.6.1.0 and later.

If the issue reported in this article occurs, Contact Technical Support | Dell US or your Authorized Service Representative for assistance, and quote this Dell article ID.

受影响的产品

PowerStore, PowerStore 1000X, PowerStore 1000T, PowerStore 1200T, PowerStore 3000X, PowerStore 3000T, PowerStore 3200T, PowerStore 5000X, PowerStore 5000T, PowerStore 500T