PowerStore: Node reboot due to rasdaemon memory leak (OOM)
摘要: A PowerStore node may reboot due to a memory leak caused by an internal process (rasdaemon).
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
Symptoms may include:
This issue only affects PowerStore appliances running releases older than PowerStoreOS 3.2.
- A single node reboot (the node automatically recovers after the reboot).
- In rare cases, both nodes may be affected by this issue simultaneously, resulting in a short service disruption.
This issue only affects PowerStore appliances running releases older than PowerStoreOS 3.2.
原因
PowerStoreOS includes a process called rasdaemon which is responsible for monitoring and reporting various CPU errors to the upper layers. The rasdaemon utility comes bundled with the PowerStoreOS. An issue has been identified that may cause a memory leak when an underlying hardware issue exists. These underlying hardware issues are typically correctable errors on DIMMs and CPU. Every time an issue is encountered the process may leak memory until no memory is left.
解决方案
This issue is fixed in PowerStoreOS 3.2.0 and later.
To determine if this issue has occurred, contact Dell Technical Support or your authorized service provider and reference this article.受影响的产品
PowerStore, PowerStoreOS文章属性
文章编号: 000207130
文章类型: Solution
上次修改时间: 15 11月 2024
版本: 6
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。