Connectrix B 系列:DS-6620B-V2 返回(“产品名称”:“未知”)到 REST API 查询
摘要: 缺陷 FOS-848976
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
DS-6620B-V2 交换机返回(“product-name”:“未知”)到 REST API 查询
[root@Connectrix-SANnav-Appliance ~]# curl -k -X GET -u admin: -H "Accept: application/yang-data+json" "https:///rest/running/brocade-chassis/chassis"
{
"Response": {
"chassis": {
"chassis-user-friendly-name": "sw01",
"license-id": "10:00:d8:1f:cc:xx:xx:xx",
"chassis-wwn": "10:00:d8:1f:cc:xx:xx:xx",
"serial-number": "FPF190xxxxx",
"manufacturer": "Brocade Communications Systems LLC",
"part-number": "40-1001258-06",
"vf-enabled": false,
"vf-supported": true,
"fcr-enabled": false,
"fcr-supported": true,
"max-blades-supported": 1,
"vendor-revision-number": "",
"vendor-part-number": "CONTRX0000662",
"vendor-serial-number": "BRCFPF190xxxxx",
"product-name": "unknown",
"date": "04/05/2023-12:46:53"
}
}
}原因
Brocade 确认这是在 FOS-848976 下打开的新缺陷,影响 DS-6620B-V2(交换机类型 183)。
sw01: admin> switchshow | grep switchType
switchType: 183.0
sw01: admin>解决方案
根据 Brocade,缺陷计划在 FOS 9.1.1c/9.2.0 中得到解决。
FOS 9.0.x 没有修复或解决方法。
FOS 9.0.x 没有修复或解决方法。
受影响的产品
Connectrix DS-6620B-V2文章属性
文章编号: 000212391
文章类型: Solution
上次修改时间: 21 6月 2023
版本: 3
从其他戴尔用户那里查找问题的答案
支持服务