PowerPath Management Appliance: Running rpowermt commands return "ERROR: ELMC720"

摘要: Running rpowermt commands return "ERROR: ELMC720: Unable to fetch token for communication. Please verify the PPMA details provided and ensure that PPMA instance is running."

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

Running rpowermt commands return the following error, and the PowerPath/VE host shows as Disconnected in the PowerPath Management Appliance (PPMA) GUI.

ERROR: ELMC720: Unable to fetch token for communication . Please verify the PPMA details provided and ensure that PPMA instance is running.

 

原因

PPMA shows that its unable to connect to the ESXi host owing to Authorization errors and soap faults from the host recorded in the logs.
It does seem to be some issue between the vCenter and the ESXi host.

 

解决方案

In this case, all the troubleshooting procedures from PPMA end were covered but the issue resolved post re-adding the ESXi host to the vCenter.

 

产品

PowerPath Management Appliance, PowerPath/VE
文章属性
文章编号: 000212433
文章类型: Solution
上次修改时间: 18 1月 2024
版本:  4
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。