PowerStore: "Encountered an irrecoverable error during command execution"
摘要: After creating the File Mobility Network IPs, the user attempts to map the IPs to the management interface, which then fails with an irrecoverable error.
症状
Mapping File Mobility Network IPs fails:Encountered an irrecoverable error during command execution, Reason obj_not_found (0xE04020040004)
原因
This issue can occur if the user reconfigures the management network and changes the MTU from the default value of 1500 to some other value and then tries to create and map File Mobility Network IPs. The mapping of File Mobility IP addresses fails with the 'irrecoverable error' issue shown above.
解决方案
This issue affects PowerStoreOS versions 3.2 and 3.5 and will be resolved in a future PowerStoreOS release.