PowerStore: "Encountered an irrecoverable error during command execution"

摘要: After creating the File Mobility Network IPs, the user attempts to map the IPs to the management interface, which then fails with an irrecoverable error.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

Mapping File Mobility Network IPs fails:
Encountered an irrecoverable error during command execution, Reason obj_not_found (0xE04020040004)

 

原因

This issue can occur if the user reconfigures the management network and changes the MTU from the default value of 1500 to some other value and then tries to create and map File Mobility Network IPs. The mapping of File Mobility IP addresses fails with the 'irrecoverable error' issue shown above.

 

解决方案

This issue affects PowerStoreOS versions 3.2 and 3.5 and will be resolved in a future PowerStoreOS release.
As a workaround, users must remove their File Mobility Networking IPs and revert management network MTU settings back to 1500. Finally, re-create the File Mobility Network IP addresses, and map the IPs to the management network.

 

受影响的产品

PowerStore
文章属性
文章编号: 000213659
文章类型: Solution
上次修改时间: 08 9月 2025
版本:  3
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。