PowerProtect: Replikace PPDM: Problém s replikací mezi produkty a zařízeními DD – Chyba při replikaci chybového kódu ARP0030
摘要: Replikace se konzistentnělhává s chybovým kódem ARP0030 problém s vypršením časového limitu mezi nástrojem PowerProtect Data Manager a systémem DR Data Domain. Například: Úloha replikace byla pro MICROSOFT_SQL_DATABASE neúspěšná. ...
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
Formulář \...\Failed_106StripMillData_PSSQLDB02.soo.algoma.com_a6d0##########9115\PowerProtect Data Manager_a6d0########9115:
Z \var\log\brs\monitoring\monitoring.log
replmgr.log: YYYY-MM-DDTHH:MM:59.888Z INFO [] [replmgr-job-worker-thread-48306] [00000000-0000-4000-a000-000000000000][][TASK_ID:ae36########44e4][TRACE_ID:911d########e63b;JOB_ID:a6d0########9115][plc.id:d3fb6870,asset.id:58f0839f,pcs.id:] c.e.b.d.ddboost.DDBoostAdapter.connect(331) - Connecting using storage unit: PPDM-PROD_VLT_MSSQL_PROCESS_PROD-ppdm-R-44576
replmgr.log: YYYY-MM-DDTHH:MM:59.888Z ERROR [] [replmgr-job-worker-thread-48306] [00000000-0000-4000-a000-000000000000][][TASK_ID:ae36########44e4][TRACE_ID:911d########e63b;JOB_ID:a6d0########9115][plc.id:d3fb6870,asset.id:58f0839f,pcs.id:] c.e.b.d.c.d.c.DdboostConnectionManager.connect(219) - Failed to connect to PowerProtect DD, rethrow exception as DdConnectionException.
com.emc.brs.datadomain.ddboost.DdboostException: Code: 5002, Message: connect operation failed with code: 5002. errstr=value exceeds upper bound, errorinfo=[ 6348] [139996585236224] Thu Oct 5 14:03:59 2023
ddp_connect_with_config() failed, Hostname: my_dr_datadomain.abc.com, Err: 5002-max allowed connections exceeded
########## ---------- ##########
./Failed_106StripMillData_PSSQLDB02.abc.com_a6d0########9115/PowerProtect Data Manager_a6d0########9115.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_106StripMillData_PSSQLDB02.abc.com_a6d0########9115/PowerProtect Data Manager_a6d0########9115.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_106StripMillData_PSSQLDB02.abc.com_a6d0########9115/PowerProtect Data Manager_a6d0########9115.log: ddp_connect_with_config() failed, Hostname: my_dr_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_Cogen_OPA_ProcessGenSQL01.abc.com_ab9dc39ded42567b/PowerProtect Data Manager_ab9dc39ded42567b.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_Cogen_OPA_ProcessGenSQL01.abc.com_ab9dc39ded42567b/PowerProtect Data Manager_ab9dc39ded42567b.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_Cogen_OPA_ProcessGenSQL01.abc.com_ab9dc39ded42567b/PowerProtect Data Manager_ab9dc39ded42567b.log: ddp_connect_with_config() failed, Hostname: my_dr_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_CraneDashboardDev_SSMXSQLSSD02.abc.com_8eff47d26bf2292f/PowerProtect Data Manager_8eff47d26bf2292f.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_CraneDashboardDev_SSMXSQLSSD02.abc.com_8eff47d26bf2292f/PowerProtect Data Manager_8eff47d26bf2292f.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_DSPC_Delays_DSPCDB01.abc.com_890b4ea199a2cbfe/PowerProtect Data Manager_890b4ea199a2cbfe.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_DSPC_Delays_DSPCDB01.abc.com_890b4ea199a2cbfe/PowerProtect Data Manager_890b4ea199a2cbfe.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_DWConfiguration_DSPCDB01.abc.com_998b66035ec5524c/PowerProtect Data Manager_998b66035ec5524c.log: ddp_connect_with_config() failed, Hostname: my_dr_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_DWConfiguration_DSPCDB01.abc.com_998b66035ec5524c/PowerProtect Data Manager_998b66035ec5524c.log: ddp_connect_with_config() failed, Hostname: my_dr_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_model_provpsdbprd.abc.com_8adc301f67163e72/PowerProtect Data Manager_8adc301f67163e72.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_model_provpsdbprd.abc.com_8adc301f67163e72/PowerProtect Data Manager_8adc301f67163e72.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_model_stldb-prod.abc.com_97a781c68e4a4476/PowerProtect Data Manager_97a781c68e4a4476.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_model_stldb-prod.abc.com_97a781c68e4a4476/PowerProtect Data Manager_97a781c68e4a4476.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_ReportServerTempDB_PSSQLDB05.abc.com_a2dd38f4a44dc164/PowerProtect Data Manager_a2dd38f4a44dc164.log: ddp_connect_with_config() failed, Hostname: my_dr_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_ReportServerTempDB_PSSQLDB05.abc.com_a2dd38f4a44dc164/PowerProtect Data Manager_a2dd38f4a44dc164.log: ddp_connect_with_config() failed, Hostname: my_dr_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_TES_stldb-prod.abc.com_8ce8c387e035c399/PowerProtect Data Manager_8ce8c387e035c399.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
./Failed_TES_stldb-prod.abc.com_8ce8c387e035c399/PowerProtect Data Manager_8ce8c387e035c399.log: ddp_connect_with_config() failed, Hostname: my_prod_datadomain.abc.com, Err: 5002-max allowed connections exceeded
Z \var\log\brs\monitoring\monitoring.log
YYYY-MM-DDTHH:MM:10.613Z INFO [] [pool-8-thread-1] [][][][TRACE_ID:86c6########bb9b][] [c.e.b.t.i.LogTracingServiceImpl.startTrace(57)] - === Start a new Log Trace for Compute System Health Metrics ===
YYYY-MM-DDTHH:MM:16.027Z INFO [] [pool-5-thread-1] [][][][][] [c.e.b.m.e.s.ExternalNotificationServiceMonitoring.getExternalNotificationsToCloseWindow(256)] - 0 External Notifications for summary email.
YYYY-MM-DDTHH:MM:21.915Z INFO [] [AsyncResolver-bootstrap-executor-0] [][][][][] [c.n.d.s.r.a.ConfigClusterResolver.getClusterEndpoints(43)] - Resolving eureka endpoints via configuration
YYYY-MM-DDTHH:MM:40.698Z INFO [] [pool-9-thread-1] [][][][TRACE_ID:a5cb15899916efb5][] [c.e.b.t.i.LogTracingServiceImpl.startTrace(57)] - === Start a new Log Trace for Compute System Manager Health Checks ===
YYYY-MM-DDTHH:MM:41.331Z INFO [] [https-jsse-nio-8449-exec-10] [][][][][] [c.e.b.a.c.AccessTokenRedeemingRequestFilter.withAuthenticationFromRequest(71)] - REDEEM: success
YYYY-MM-DDTHH:MM:41.331Z INFO [] [https-jsse-nio-8449-exec-10] [][][][TRACE_ID:a5cb15899916efb5][] [c.e.b.m.f.RestLogFilter.doFilter(45)] - Enter RESTful Msg - Method: GET , Path: https://localhost:8443/api/v2/report-nodes
YYYY-MM-DDTHH:MM:41.475Z INFO [] [https-jsse-nio-8449-exec-10] [][][][][] [c.e.b.m.f.RestLogFilter.doFilter(56)] - Exit RESTful Msg - Status: 200 , ContentType: application/json
YYYY-MM-DDTHH:MM:01.335Z INFO [] [https-jsse-nio-8449-exec-2] [][][][][] [c.e.b.a.c.AccessTokenRedeemingRequestFilter.withAuthenticationFromRequest(71)] - REDEEM: success
YYYY-MM-DDTHH:MM:01.336Z INFO [] [https-jsse-nio-8449-exec-2] [][][][TRACE_ID:a1f2ee14131a5ccd][] [c.e.b.m.f.RestLogFilter.doFilter(45)] - Enter RESTful Msg - Method: GET , Path: https://myppdm.abc.com:8443/api/v2/activities ?filter=category+in+%28%22PROTECT%22%2C%22RESTORE%22%2C%22SYSTEM%22%2C%22EXPORT_REUSE%22%2C%22REPLICATE%22%2C%22CONFIG%22%2C%22VALIDATE%22%2C%22CLOUD_TIER%22%2C%22CLOUD_DR%22%2C%22DISCOVER%22%2C%22NOTIFY%22%2C%22DELETE%22%2C%22MANAGE%22%2C%22DISASTER_RECOVERY%22%29+and+classType+in+%28%22JOB_GROUP%22%2C%22JOB%22%29+and+%28%28updateTime+gt+%222023-10-05T17%3A53%3A25.002Z%22+and+updateTime+le+%222023-10-05T17%3A58%3A30.002Z%22+and+state+ne+%22COMPLETED%22%29+or+%28endTime+gt+%222023-10-05T17%3A53%3A25.002Z%22+and+endTime+le+%222023-10-05T17%3A58%3A30.002Z%22%29%29&orderby=startTime&pageSize=5000&queryState=BEGIN
YYYY-MM-DDTHH:MM:01.357Z INFO [] [https-jsse-nio-8449-exec-2] [][][][][] [c.e.b.m.f.RestLogFilter.doFilter(56)] - Exit RESTful Msg - Status: 200 , ContentType: application/json
YYYY-MM-DDTHH:MM:15.713Z INFO [] [pool-5-thread-1] [][][][][] [c.e.b.m.e.s.ExternalNotificationServiceMonitoring.getExternalNotificationsToCloseWindow(256)] - 0 External Notifications for summary email.
################ ---------- ################ ---------- ################ ---------- ################
YYYY-MM-DDTHH:MM:00.094Z INFO [] [not.a.Spring.bean-8] [][][TASK_ID:9d91be8fab969815][TRACE_ID:911d########e63b;JOB_ID:998b66035ec5524c][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"7ead8219-ca50-4dd8-9d91-be8fab969815","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:00.099Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 7ead8219-ca50-4dd8-9d91-be8fab969815, messageID ARP0030.
YYYY-MM-DDTHH:MM:00.375Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:00.375Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(223)] - Creating newAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 7ead8219-ca50-4dd8-9d91-be8fab969815, messageID: ARP0030
YYYY-MM-DDTHH:MM:00.483Z INFO [] [https-jsse-nio-8449-exec-5] [][][][][] [c.e.b.a.c.AccessTokenRedeemingRequestFilter.withAuthenticationFromRequest(71)] - REDEEM: success
YYYY-MM-DDTHH:MM:00.483Z INFO [] [https-jsse-nio-8449-exec-5] [][][][TRACE_ID:b4dbb37c03557ba7][] [c.e.b.m.f.RestLogFilter.doFilter(45)] - Enter RESTful Msg - Method: GET , Path: https://myppdm.abc.com:8443/api/v2/alerts/b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39
YYYY-MM-DDTHH:MM:00.488Z INFO [] [https-jsse-nio-8449-exec-5] [][][][][] [c.e.b.m.f.RestLogFilter.doFilter(56)] - Exit RESTful Msg - Status: 200 , ContentType: application/json
YYYY-MM-DDTHH:MM:04.321Z INFO [] [not.a.Spring.bean-1] [][][TASK_ID:ab2ac64b7c2ec32c][TRACE_ID:911d########e63b;JOB_ID:ab9dc39ded42567b][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"721273bd-23e5-4ddd-ab2a-c64b7c2ec32c","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:04.322Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 721273bd-23e5-4ddd-ab2a-c64b7c2ec32c, messageID ARP0030.
YYYY-MM-DDTHH:MM:04.327Z INFO [] [not.a.Spring.bean-5] [][][TASK_ID:b2e7a5ced8379d07][TRACE_ID:911d########e63b;JOB_ID:a2dd38f4a44dc164][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"8923eb9c-997e-45f0-b2e7-a5ced8379d07","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:04.337Z INFO [] [not.a.Spring.bean-4] [][][TASK_ID:a64cb2db470779a2][TRACE_ID:911d########e63b;JOB_ID:8adc301f67163e72][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"81df708e-6406-4900-a64c-b2db470779a2","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:04.371Z INFO [] [not.a.Spring.bean-7] [][][TASK_ID:ae36########44e4][TRACE_ID:911d########e63b;JOB_ID:a6d0########9115][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"3026f531-1fdc-4e1f-ae36-edf3c6a044e4","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:05.225Z INFO [] [not.a.Spring.bean-2] [][][TASK_ID:b9058ca36192e544][TRACE_ID:862d0db52e63ef03;JOB_ID:8e4c099fd821b4a2][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"a1079476-fc94-44c5-b905-8ca36192e544","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:05.280Z INFO [] [not.a.Spring.bean-6] [][][TASK_ID:9985aa79a8cbd17d][TRACE_ID:862d0db52e63ef03;JOB_ID:9f74f0e898e21669][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"e8058a39-a816-4d09-9985-aa79a8cbd17d","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:05.367Z INFO [] [not.a.Spring.bean-3] [][][TASK_ID:9aecaba1c9b27a55][TRACE_ID:911d########e63b;JOB_ID:890b4ea199a2cbfe][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"3bc94ee5-21e5-4119-9aec-aba1c9b27a55","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:05.373Z INFO [] [not.a.Spring.bean-8] [][][TASK_ID:abd3940d23f110e7][TRACE_ID:911d########e63b;JOB_ID:97a781c68e4a4476][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"fdd4f333-db04-430b-abd3-940d23f110e7","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:05.384Z INFO [] [not.a.Spring.bean-10] [][][TASK_ID:836373542d1eaeff][TRACE_ID:911d########e63b;JOB_ID:8ce8c387e035c399][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"7bf67f00-a691-4d37-8363-73542d1eaeff","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:05.434Z INFO [] [not.a.Spring.bean-1] [][][TASK_ID:b525c4bdf4612dc7][TRACE_ID:911d########e63b;JOB_ID:8eff47d26bf2292f][] [c.e.b.m.a.n.ActivityAlertNotificationHandler.handleMessage(54)] - Activity state change notification message received. body: {"activityId":"883332f8-0a64-4231-b525-c4bdf4612dc7","messageID":"ARP0030"}
YYYY-MM-DDTHH:MM:06.092Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:06.092Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 721273bd-23e5-4ddd-ab2a-c64b7c2ec32c, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:06.321Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 8923eb9c-997e-45f0-b2e7-a5ced8379d07, messageID ARP0030.
YYYY-MM-DDTHH:MM:07.853Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:07.853Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 8923eb9c-997e-45f0-b2e7-a5ced8379d07, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:07.896Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 81df708e-6406-4900-a64c-b2db470779a2, messageID ARP0030.
YYYY-MM-DDTHH:MM:09.571Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:09.571Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 81df708e-6406-4900-a64c-b2db470779a2, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:09.667Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 3026f531-1fdc-4e1f-ae36-edf3c6a044e4, messageID ARP0030.
YYYY-MM-DDTHH:MM:10.367Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:10.367Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 3026f531-1fdc-4e1f-ae36-edf3c6a044e4, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:10.471Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId a1079476-fc94-44c5-b905-8ca36192e544, messageID ARP0030.
YYYY-MM-DDTHH:MM:10.687Z ERROR [] [pool-8-thread-1] [][][][TRACE_ID:86c6########bb9b][] [c.d.b.m.h.i.SystemHealthServiceImpl.computeSystemHealthMetrics(129)] - Failed to compute system health metrics
java.util.concurrent.CompletionException: com.dell.brs.monitoring.health.exception.HealthServiceException: Health Check: SupportConfigHealthCheck timed out.
at java.base/java.util.concurrent.CompletableFuture.encodeThrowable(CompletableFuture.java:314)
at java.base/java.util.concurrent.CompletableFuture.completeThrowable(CompletableFuture.java:319)
at java.base/java.util.concurrent.CompletableFuture.uniExceptionally(CompletableFuture.java:990)
at java.base/java.util.concurrent.CompletableFuture$UniExceptionally.tryFire(CompletableFuture.java:970)
at java.base/java.util.concurrent.CompletableFuture.postComplete(CompletableFuture.java:506)
at java.base/java.util.concurrent.CompletableFuture.completeExceptionally(CompletableFuture.java:2088)
at java.base/java.util.concurrent.CompletableFuture$Timeout.run(CompletableFuture.java:2792)
at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
at java.base/java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFutureTask.run(ScheduledThreadPoolExecutor.java:304)
at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.dell.brs.monitoring.health.exception.HealthServiceException: Health Check: SupportConfigHealthCheck timed out.
at com.dell.brs.monitoring.health.SystemHealthCalculatorImpl.lambda$computeHealthChecks$13(SystemHealthCalculatorImpl.java:309)
at java.base/java.util.concurrent.CompletableFuture.uniExceptionally(CompletableFuture.java:986)
... 10 common frames omitted
Caused by: java.util.concurrent.TimeoutException: null
... 7 common frames omitted
YYYY-MM-DDTHH:MM:10.688Z INFO [] [pool-8-thread-1] [][][][TRACE_ID:bb798ef84b9e2a29][] [c.e.b.t.i.LogTracingServiceImpl.startTrace(57)] - === Start a new Log Trace for Compute System Health Metrics ===
YYYY-MM-DDTHH:MM:11.074Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:11 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_DEV: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE CokemakingDev on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:11.074Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(223)] - Creating newAlertId: 8edc9bb2-65b6-40a6-9ebb-aa61536e8378 for ancestryId: 16b707c2-7c84-4f21-9046-a1f4cac8923d, activityId: a1079476-fc94-44c5-b905-8ca36192e544, messageID: ARP0030
YYYY-MM-DDTHH:MM:11.121Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId e8058a39-a816-4d09-9985-aa79a8cbd17d, messageID ARP0030.
YYYY-MM-DDTHH:MM:11.162Z INFO [] [https-jsse-nio-8449-exec-9] [][][][][] [c.e.b.a.c.AccessTokenRedeemingRequestFilter.withAuthenticationFromRequest(71)] - REDEEM: success
YYYY-MM-DDTHH:MM:11.162Z INFO [] [https-jsse-nio-8449-exec-9] [][][][TRACE_ID:8b1fec7af5b93e3d][] [c.e.b.m.f.RestLogFilter.doFilter(45)] - Enter RESTful Msg - Method: GET , Path: https://myppdm.abc.com:8443/api/v2/alerts/8edc9bb2-65b6-40a6-9ebb-aa61536e8378
YYYY-MM-DDTHH:MM:11.249Z INFO [] [https-jsse-nio-8449-exec-9] [][][][][] [c.e.b.m.f.RestLogFilter.doFilter(56)] - Exit RESTful Msg - Status: 200 , ContentType: application/json
YYYY-MM-DDTHH:MM:11.764Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:11 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_DEV: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE CokemakingDev on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:11.764Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: 8edc9bb2-65b6-40a6-9ebb-aa61536e8378 for ancestryId: 16b707c2-7c84-4f21-9046-a1f4cac8923d, activityId: e8058a39-a816-4d09-9985-aa79a8cbd17d, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:11.799Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 3bc94ee5-21e5-4119-9aec-aba1c9b27a55, messageID ARP0030.
YYYY-MM-DDTHH:MM:12.474Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:12.475Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 3bc94ee5-21e5-4119-9aec-aba1c9b27a55, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:12.561Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId fdd4f333-db04-430b-abd3-940d23f110e7, messageID ARP0030.
YYYY-MM-DDTHH:MM:12.927Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:12.927Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: fdd4f333-db04-430b-abd3-940d23f110e7, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:12.966Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 7bf67f00-a691-4d37-8363-73542d1eaeff, messageID ARP0030.
YYYY-MM-DDTHH:MM:13.195Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
YYYY-MM-DDTHH:MM:13.195Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 7bf67f00-a691-4d37-8363-73542d1eaeff, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:13.233Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(196)] - activityId 883332f8-0a64-4231-b525-c4bdf4612dc7, messageID ARP0030.
YYYY-MM-DDTHH:MM:13.356Z ERROR [] [pool-4-thread-1] [][ALERT:ARP0030][][][] [c.e.d.e.c.s.m.DefaultMessageResourceModifier.printAlertLog(143)] - Date: MMM DD, YYYY 14:04:00 PM; Summary: PPDM-PROD_VLT_MSSQL_PROCESS_PROD: Replication job was unsuccessful for MICROSOFT_SQL_DATABASE DWConfiguration on my_prod_datadomain.abc.com to my_dr_datadomain.abc.com because of data movement error.; Details: The backup copies cannot be replicated because data movement for the copies on the the storage system was unsuccessful.; Recommended Action: Follow the procedure in the PowerProtect Data Manager Administration and User Guide to create a log bundle, and then contact Dell Customer Support.; Detail Summaries: null; Status: UNACKNOWLEDGED
>>>>>>>>>>>> YYYY-MM-DDTHH:MM:13.357Z INFO [] [pool-4-thread-1] [][][][][] [c.e.b.m.a.s.ActivityAlertService.createOrUpdateAlert(216)] - Updating existingAlertId: b86e8c2a-52e3-4e71-8bbd-3b82f0c7da39 for ancestryId: 51ea3ef5-8e03-429c-ad18-e86eb9e7263f, activityId: 883332f8-0a64-4231-b525-c4bdf4612dc7, messageID: ARP0030 instead of creating new alert
YYYY-MM-DDTHH:MM:15.765Z INFO [] [pool-5-thread-1] [][][][][] [c.e.b.m.e.s.ExternalNotificationServiceMonitoring.getExternalNotificationsToCloseWindow(256)] - 0 External Notifications for summary email.
YYYY-MM-DDTHH:MM:40.697Z INFO [] [pool-9-thread-1] [][][][TRACE_ID:a5d20d83be23e52a][] [c.e.b.t.i.LogTracingServiceImpl.startTrace(57)] - === Start a new Log Trace for Compute System Manager Health Checks ===
YYYY-MM-DDTHH:MM:40.818Z INFO [] [https-jsse-nio-8449-exec-3] [][][][][] [c.e.b.a.c.AccessTokenRedeemingRequestFilter.withAuthenticationFromRequest(71)] - REDEEM: success
YYYY-MM-DDTHH:MM:40.819Z INFO [] [https-jsse-nio-8449-exec-3] [][][][TRACE_ID:a5d20d83be23e52a][] [c.e.b.m.f.RestLogFilter.doFilter(45)] - Enter RESTful Msg - Method: GET , Path: https://localhost:8443/api/v2/report-nodes
YYYY-MM-DDTHH:MM:40.839Z INFO [] [https-jsse-nio-8449-exec-3] [][][][][] [c.e.b.m.f.RestLogFilter.doFilter(56)] - Exit RESTful Msg - Status: 200 , ContentType: application/json
YYYY-MM-DDT18:05:15.702Z INFO [] [pool-5-thread-1] [][][][][] [c.e.b.m.e.s.ExternalNotificationServiceMonitoring.getExternalNotificationsToCloseWindow(256)] - 0 External Notifications for summary email.
YYYY-MM-DDT18:06:10.712Z ERROR [] [pool-8-thread-1] [][][][TRACE_ID:bb798ef84b9e2a29][] [c.d.b.m.h.i.SystemHealthServiceImpl.computeSystemHealthMetrics(129)] - Failed to compute system health metrics
java.util.concurrent.CompletionException: com.dell.brs.monitoring.health.exception.HealthServiceException: Health Check: SupportConfigHealthCheck timed out.
原因
Dojde k vypršení časového limitu připojení mezi nástrojem PowerProtect Data Manager a zařízením Data Domain. Způsobuje selhání replikace s chybovým kódem ARP0030.
解决方案
V rozhraní příkazového řádku nástroje PowerProtect Data Manager proveďte následující kroky:
1. Vytvořte soubor /usr/local/brs/lib/replmgr/config/application.properties:
3. Spusťte příkaz:
4. Spusťte příkaz:
5. Přidejte tento řádek:
6. Uložte soubor – Spustit:
7. Restartujte nástroj replmgr – Spustit:
8. Otestujte replikaci.
1. Vytvořte soubor /usr/local/brs/lib/replmgr/config/application.properties:
touch /usr/local/brs/lib/replmgr/config/application.properties 2. Spusťte příkaz:
chmod ug+rx /usr/local/brs/lib/replmgr/config/application.properties
chown admin:app /usr/local/brs/lib/replmgr/config/application.properties
vi /usr/local/brs/lib/replmgr/config/application.properties
ddboost.dynamic.connection.check.enable=false
ddboost.dedicated.connection.max.coun=64
ddboost.shared.connection.max.count=64
:x!
replmgr restart
产品
PowerProtect Software文章属性
文章编号: 000218427
文章类型: Solution
上次修改时间: 23 10月 2024
版本: 4
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。