Connectrix B-Series: After Upgrading to Fabric OS 9.1.1c, Inline Commands with the Use of "fosexec" Command Return an Error

摘要: After upgrading to Fabric OS (FOS) 9.1.1c, unable to run inline commands from UNIX or Linux server to the switch with the "fosexec" commands.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

Environment:

Fabric OS 9.1.1c

Issue:

The outputs show errors when running an inline command from a UNIX or Linux server. The command stops responding when probing a different logical Switch FID on the same chassis. Example:

[hosttest@VM1234 ~]$
[hosttest@VM1234 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@aa.bb.cc.dd's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
/etc/ssh_inline_profile: line 25: FUNCNEST: readonly variable
Appl     Primary/Secondary Versions
------------------------------------------
FOS      v9.1.1c
         v9.1.1c
---------------------------------------------------

"firmwareshow" on FID 44:

[hosttest@VM3198 ~]$

原因

This issue was found during internal testing. A change in the error was found when upgrade to FOS 9.2.0a was done.

Error:
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@10.60.23.25's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
Appl     Primary/Secondary Versions
------------------------------------------
FOS      v9.2.0a
         v9.2.0a
---------------------------------------------------

"firmwareshow" on FID 44:

[hosttest@VM3198 ~]$

解决方案

Resolution:

Upgrade to Fabric OS 9.2.0b or later.

Workaround:

Run the commands directly on the switch.

受影响的产品

Connectrix, Connectrix B-Series

产品

Connectrix B-Series Fabric OS 9.X
文章属性
文章编号: 000218645
文章类型: Solution
上次修改时间: 29 7月 2025
版本:  4
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。