DLm: DLm System Manager (DSM) cannot select higher numbered VTEs when configuring file systems
摘要: Filesystems cannot be configured to VTEs by DSM when the selected VTE is on the second line in the popup window.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
This article is applicable as follows:
Using DLm System Manager > Tape Libraries > Add xx Filesystems option.
If the VTE candidate list spans two lines, then selecting VTE on the second line is not possible. It shows in the panel as selection of a VTE on the first line:
In the following capture, selection of VTE6 registers in DSM as selection of VTE2:
原因
Code Error
解决方案
This is corrected in DLm firmware V5.5.0.4 and later release.
Workaround
Select file systems one by one, which can present more VTE for selection from the first line:
受影响的产品
Disk Library for mainframe DLm8500文章属性
文章编号: 000219127
文章类型: Solution
上次修改时间: 20 8月 2024
版本: 2
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。