症状

线卡插入先前填充的 MDS 控制器插槽时无法启动。

当新线卡与原始线卡的型号相同时,会看到以下 syslog 消息:

%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Speed group configuration is not supported. (0x4029018c)

如果新线卡与原始线卡的型号不同,则会看到以下系统日志消息:

%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 10 to come up for reason: Speed change not allowed (0x4029007f)

在这两种情况下,都会记录以下系统日志序列:

%VMM-2-VMM_SERVICE_ERR: VDC1: Service SAP Port manager (high) for slot 8 returned error 0x402901ac (Module insertion failed) in if_bind sequence

%IM-3-IM_RESP_ERROR: Component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND in vdc:1 returned error:Module insertion failed

%IM-3-IM_SEQ_ERROR: Error (Module insertion failed) while communicating with component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND (for:RID_MODULE: 8)

%MODULE-2-LCM_MODULE_INSERT_FAILURE_NEG_RSP: Slot-8 has failed to boot up because of service "Im SAP" due to module insertion failure

模块最终进入 故障 状态,如下图所示 show module command: 


Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
1    34     1/10/40G IPS,2/4/8/10/16G FC Module DS-X9334-K9        failure

Mod  Power-Status  Reason
---  ------------  ---------------------------
1    failure        Unknown. Issue show system reset mod ...

原因

Cisco 互作性问题

解决方案

解决方法:
要防止出现此问题,请运行以下命令 purge module x running-config 插槽为空时。

如果问题已经发生,请备份配置并运行以下会造成中断的命令。

write erase
write erase boot
reload

已知修复版本:

受影响的产品

Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9710-V2, Connectrix MDS-9718, Connectrix MDS-Series Hardware